437

Example

# Configure the link layer protocol and operating mode of Serial 2/0 as LAPB and

 

DCE.

 

<Sysname> system-view

 

[Sysname] interface serial 2/0

 

[Sysname-Serial2/0] link-protocol lapb dce

 

 

link-protocol x25

 

Syntax

link-protocol x25 [ dce dte ] [ ietf nonstandard ]

View

Interface view

Parameter

dce: Specifies the DCE mode.

 

dte: Specifies the DTE mode.

 

letf: Encapsulates IP or other network protocols on the X.25 network based on

 

the standard stipulation of the IETF RFC 1356.

 

nonstandard: Nonstandard encapsulates IP or other network protocols on the

 

X.25 network.

Description

Use the link-protocol x25 command to encapsulate X.25 protocol on the

 

specified interface.

 

By default, the link-layer protocol for the interface is PPP. When the interface uses

 

X.25 protocol, it works in DTE IETF mode by default.

 

Note that:

 

When two Routers are connected via the X.25 public packet network, they shall

 

work as DTE and use IETF format.

 

If two Routers are directly connected, one Router shall work as DTE, the other as

 

DCE. Both parties should use the same data format.

 

If the X.25 switching function is used, the device should work as DCE.

 

In practice, select the IETF format if there is no special requirement.

Example

# Specify X.25 as the link layer protocol of the interface Serial2/0 that works in

 

DTE IETF mode.

 

<Sysname> system-view

 

[Sysname] interface serial 2/0

 

[Sysname-Serial2/0] link-protocol x25 dte ietf

 

 

pad

 

Syntax pad x121-address

Page 437
Image 437
3Com MSR 50, MSR 30 manual Pad, Link-protocol x25 dce dte ietf nonstandard