203
When the CE1/PRI interface is working as DCE, choose the internal clock (master)
for it. When it is working as DTE, choose the line clock for it.
Example # Use the internal clock as the clock source on CE1/PRI interface E1 2/0.
<Sysname> system-view
[Sysname] controller e1 2/0
[Sysname-E1 2/0] clock master
code (CEI/PRI interface view)
Syntax code { ami | hdb3 }
undo code
View CE1/PRI interface view
Parameter ami: Adopts alternate mark inversion (AMI) line code format.
hdb3: Adopts high density bipolar 3 (HDB3) line code format.
Description Use the code command to set the line code format for the CE1/PRI interface.
Use the undo code command to restore the default, that is, HDB3.
Keep the line code format of the interface in consistency with that used by the
remote device.
Example # Set the line code format of interface E1 2/0 to AMI.
<Sysname> system-view
[Sysname] controller e1 2/0
[Sysname-E1 2/0] code ami
controller e1
Syntax controller e1 number
View System view
Parameter number: CE1/PRI interface number.
Description Use the controller e1 command to enter CE1/PRI interface view.
Example # Enter E1 2/0 interface view.
<Sysname> system-view
[Sysname] controller e1 2/0
[Sysname-E1 2/0]