2653

undo dl-bits { answer blocking clear-back clear-forward idle seize seizure-ack release-guard } { received transmit }

View R2 CAS view

Parameter answer: Answer signal of R2 line signaling.

blocking: Blocking signal of R2 line signaling.

clear-back: Clear-back signal of R2 line signaling.

clear-forward: Clear-forward signal of R2 line signaling.

idle: Idle signal of R2 line signaling.

seize: Seizure signal of R2 line signaling.

seizure-ack: Seizure acknowledgement signal of R2 line signaling.

release-guard: Release guard signal of R2 line signaling.

received: Indicates that the signaling setting applies to received R2 line signals.

transmit: Indicates that the signaling setting applies to transmitted R2 line signals.

ABCD: ABCD bit pattern of R2 line signaling, in the range of 0000 to 1111.

Table 695 Default values of signals in R2 digital line signaling

Signal

Default rx-bits ABCD

Default tx-bits ABCD

 

 

 

Answer

0101

0101

Blocking

1101

1101

Clear-back

1101

1101

Clear-forward

1001

1001

Idle

1001

1001

Seize

0001

0001

Seizure-ack

1101

1101

Release-guard

1001

1001

 

 

 

Description Use the dl-bitscommand to configure the ABCD bit pattern for R2 signals.

Use the undo dl-bitscommand to restore the defaults.

This command applies to R2 signaling only.

You may need to use this command to accommodate to the ABCD bit pattern schemes used in different countries.

When you modify the ABCD bit pattern of a signal, you need to modify the ABCD bit pattern of other signals accordingly so that the whole signaling system can work normally.

Page 2653
Image 2653
3Com MSR 50 Default values of signals in R2 digital line signaling, 2653, Signal Default rx-bits Abcd Default tx-bits Abcd