356CHAPTER 21: BASIC DLSW CONFIGURATION COMMANDS

View Ethernet interface view

Parameter mseconds: LLC2 local acknowledgment delay, in milliseconds. The effective range is 1 to 60,000.

Description Use the llc2 timer ack-delaycommand to configure the LLC2 local acknowledgment delay time, namely the maximum length of time the device waits before sending an acknowledgment to the peer end upon receiving an LLC2 frame.

Use the undo llc2 timer ack-delaycommand to restore the default setting.

By default, the LLC2 local acknowledgment delay time is 100 milliseconds.

Example # Set the LLC2 local acknowledgment delay time to 200 milliseconds on Ethernet 1/0.

<Sysname> system-view

[Sysname] interface ethernet 1/0

[Sysname-Ethernet1/0] llc2 timer ack-delay 200

llc2 timer busy

Syntax llc2 timer busy mseconds

undo llc2 timer busy

View Ethernet interface view

Parameter mseconds: LLC2 busy-station polling interval, in milliseconds. The effective range is 1 to 60,000. The system default is 300 milliseconds.

Description Use the llc2 timer busy command to configure the LLC2 busy-station polling interval, namely the amount of time the router waits before repelling a busy station.

Use the undo llc2 timer busy command to restore the default setting.

Example # Set the LLC2 busy-station polling interval to 200 milliseconds on Ethernet 1/0.

<Sysname> system-view

[Sysname] interface ethernet 1/0

[Sysname-Ethernet1/0] llc2 timer busy 200

llc2 timer detect

Syntax llc2 timer detect mseconds

undo llc2 timer detect

Page 356
Image 356
3Com MSR 30, MSR 50 manual Llc2 timer busy, Llc2 timer detect, Syntax llc2 timer busy mseconds Undo llc2 timer busy