2668 CHAPTER 175: E1 AND T1 CONFIGURATION COMMANDS

 

<Sysname> system-view

 

[Sysname] controller e1 1/0

 

[Sysname-e1 1/0] timeslot-set 5 timeslot-list 1-31 signal r2

 

[Sysname-e1 1/0] cas 5

 

[Sysname-cas1/0:5] sendring ringbusy enable

 

 

signal-value

 

Syntax

signal-value { received idle received seize transmit idle transmit seize } ABCD

 

undo signal-value { received idle received seize transmit idle transmit seize }

View

Digital E&M voice subscriber line view

Parameter

received idle: Indicates the receive idle signal of digital E&M signaling.

 

received seize: Indicates the receive seized signal of digital E&M signaling.

 

transmit idle: Indicates the transmit idle signal of digital E&M signaling.

 

transmit seize: Indicates the transmit seized signal of digital E&M signaling.

 

ABCD: Default ABCD bit pattern during transmission, with each bit taking the

 

value of 0 or 1.

Description

Use the signal-valuecommand to configure the ABCD bit patterns of idle

 

receive, receive seized, idle transmit, and transmit seized signals on the digital

 

E&M voice subscriber line.

 

Use the undo signal-valuecommand to restore the defaults.

 

By default, the ABCD bit patterns of the receive idle signal and the transmit idle

 

signal are 1101, and the ABCD bit patterns of the receive seized signal and the

 

transmit seized signal are 0101. After changing the ABCD bit pattern of a digital

 

E&M signal, you must shut down the digital E&M subscriber line with the

 

shutdown command and then bring the line up with the undo shutdown

 

command. Otherwise, the voice subscriber line cannot work normally.

Related command:

subscriber line.

Example

# Set the ABCD bit pattern to 1011 for the transmit seized signal on digital E&M

 

subscriber line 1/0:0.

 

<Sysname> system-view

 

[Sysname] voice-setup

 

[Sysname-voice] subscirber-line1/0:0

 

[Sysname-voice-line1/0:0] signal-value transmit seize 1011

 

 

special-character

 

Syntax special-character character number

Page 2668
Image 2668
3Com MSR 30, MSR 50 manual Signal-value, Special-character, Related command Subscriber line Example