2264 CHAPTER 148: DEVICE MANAGEMENT COMMANDS

Description Use the temperature-alarm enable command to enable the temperature alarm function.

Use the undo temperature-alarm enable command to disable the temperature alarm function.

By default, the temperature alarm function is enabled.

Example # Enable the temperature alarm function.

<Sysname> system-view

[Sysname] temperature-alarm enable

temperature-limit

Syntax temperature-limitslot-number lower-value upper-value

undo temperature-limit slot-number

View System view

Parameter slot-number: Slot number. The value range varies with devices. lower-value: Lower temperature limit in Celsius degrees, in the range 0 to 30. upper-value: Upper temperature limit in Celsius degrees, in the range 40 to 90.

Description Use the temperature-limitcommand to set the temperature alarm threshold on a card.

Use the undo temperature-limitcommand to restore the temperature alarm threshold to the default.

By default, the lower value and the upper value of the temperature alarm threshold is 5 and 60 respectively.

Example # Set the lower temperature limit on card 0 to 10 Celsius degrees and the upper temperature limit to 75 Celsius degrees.

<Sysname> system-view

[Sysname] temperature-limit 0 10 75

Setting temperature limit succeeded.

Page 2264