2224 CHAPTER 145: BACKUP CENTER CONFIGURATION COMMANDS

Related commands:

n

This command and the standby interface command cannot be configured at the same time. That is, if you have configured the standby interface command on the main interface, you cannot configure the standby track command on both the main interface and its backup interface; if you have associated an interface with a Track object, you cannot configure the interface as the main interface or a backup interface.

One interface can be associated with one Track object. If you execute this command repeatedly on one interface, the new configuration will overwrite the original one.

You can associate an interface with a nonexistent Track object. The track function can take effect after the Track object is created with the track command.

standby interface, track on page 2529.

Support for this command varies with devices.

Examples # Configure interface Serial 2/0 to be associated with Track object 1.

<Sysname> system-view

[Sysname] interface serial 2/0

[Sysname-Serial2/0] standby track 1

Page 2224
Image 2224
3Com MSR 30, MSR 50 manual Related commands, Standby interface, track on