CPOS INTERFACE CONFIGURATION

45 COMMANDS

n E1only.- and T1-related commands are available for the CPOS (E) interface modules

clock

Syntax

clock { master slave }

 

undo clock

View

CPOS interface view

Parameter

master: Sets the clock mode of the CPOS interface to master.

 

slave: Sets the clock mode of the CPOS interface to slave.

Description

Use the clock command to set the clock mode of the CPOS interface.

 

Use the undo clock command to restore the default, that is, slave.

 

When connected to a SONET/SDH device, the CPOS interface must use the slave

 

clock because the SONET/SDH network clock is more precise. When the interface

 

is directly connected to another CPOS interface with fiber-optic, you only need to

 

configure them with different clock modes.

Example

# Set the clock mode of interface CPOS 1/0 to master.

 

<Sysname> system-view

 

[Sysname] controller cpos 1/0

 

[Sysname-Cpos1/0] clock master

controller cpos

Syntax

controller cpos cpos-number

View

System view

Parameter

cpos-number: CPOS interface number.

Description Use the controller cpos command to enter CPOS interface view.

Page 671
Image 671
3Com MSR 50, MSR 30 manual Cpos Interface Configuration Commands, Controller cpos, System view