2663

req-callingcategoryvalue: Specifies the send calling category signal value, in the range 1 to 16.

req-currentcallednum-in-groupc value: Specifies the send current called number signal in Group C state, in the range 1 to 16.

req-currentdigitvalue: Specifies the send current digit signal, in the range 1 to 16.

req-firstcallednum-in-groupcvalue: Specifies the send first digit signal value in Group C state, in the range 1 to 16.

req-firstcallingnumvalue: Specifies the send calling number signal value, in the range 1 to 16.

req-firstdigitvalue: Specifies the send first digit signal value, in the range 1 to 16.

req-lastfirstdigitvalue: Specifies the send last digit signal value, in the range 1 to 16.

req-lastseconddigitvalue: Specifies the send last second digits signal value, in the range 1 to 16.

req-lastthirddigitvalue: Specifies the send last three digits signal value, in the range 1 to 16.

req-nextcallednumvalue: Specifies the send next called number signal value, in the range 1 to 16.

req-nextcallingnumvalue: Specifies the send next calling number signal value, in the range 1 to 16.

req-switch-groupbvalue: Specifies the changeover to Group B signal value, in the range 1 to 16.

subscriber-abnormalvalue: Specifies the subscriber’s line abnormal signal value, in the range 1 to 16.

subscriber-busyvalue: Specifies the subscriber’s line busy signal value, in the range 1 to 16.

subscriber-idlevalue: Specifies the subscriber’s line idle value, in the range 1 to

16.It configures the R2 KB signal used for describing the called subscriber’s line status, for example, whether the line is idle. It acknowledges and controls call connection. If your router is connected to a PBX, change the KB value on the router to that used on the PBX, in case different KB values are used. If your router is connected to another router, you only need to make sure that the same KB signal value is used between them.

The defaults vary by national variant.

Description Use the register-valuecommand to configure R2 register signal values.

Use the undo register-valuecommand to restore the defaults.

Page 2663
Image 2663
3Com MSR 50, MSR 30 manual 2663