Step 2:

Press Input again.

The symbols “g,” or “lb”, “min” and the screw symbol flash.

After the “2”quickly flashes on the display, a number in the format xx.xxx will come up on the display.

Enter the shot weight using the arrow keys. The range of values that can be entered is 001.0 to 6500 grams (0.01 to 14.30 pounds).

Step 3:

“3” = screw recovery time in seconds

Press Input a third time.

The screw and “s” symbols flash.

After “3” flashes quickly on the display, a number in the format xxx.xx will come up on the display.

Enter the screw recovery time in seconds. This time represents the amount of time the molding machine screw is in recovery. This value is an estimate. The Digital Dosing unit measures the actual recovery time and automatically updates this value during operation. NOTE: The range of values that can be entered in this field is 2.00 to 99.99 seconds.

Digital Dosing Units

25

Page 25
Image 25
Sterling Plumbing 882 00276.00 specifications Step