Sterling Plumbing 882 00276.00 Cleaning the DD Digital Dosing Station, Installing the shear plate

Models: 882 00276.00

1 79
Download 79 pages 6.69 Kb
Page 47
Image 47

6.Remove the dosing unit from the dosing motor.

7.Remove the cover from the connecting piece (D).

8.Loosen the two screws (C) on the underside of the dosing unit housing (E).

9.Remove the shear plate (A).

Installing the shear plate

1.Place the new shear plate in the dosing unit housing.

2.Ensure that the shear plate is positioned correctly.

3.Screw the shear plate in place by means of 2 hexagon socket screws (M5 x 16).

4.Turn the dosing disc to check for smooth movement.

5.Mount the cover on the connecting piece.

6.Position the dosing unit on the dosing motor (note guide pins).

7.Close the toggle-type fasteners on the dosing motor.

8.Mount the safety screws.

9.Position the dosing hopper on the dosing unit.

10.Mount the profile clamp.

11.Mount the screw at the profile clamp.

5.3 Cleaning the “DD” Digital Dosing Station

Dismantling the Dosing Station

1.Empty the dosing station.

2.Switch the control unit off by means of the on/off switch.

3.Disconnect from main voltage.

4.Open the profile clamp on the dosing hopper.

Digital Dosing Units

47

Page 47
Image 47
Sterling Plumbing 882 00276.00 specifications Cleaning the DD Digital Dosing Station, Installing the shear plate