Sterling Plumbing 882 00276.00 Determining the Software Setup Factor, Recipe Formulas

Models: 882 00276.00

1 79
Download 79 pages 6.69 Kb
Page 56
Image 56

A.3 Determining the Software Setup Factor

The Digital Dosing control unit is configured via a Software Setup Factor (binary code). To determine the Software Setup Factor answer the following questions: If the answer is “yes” enter the code number in the selection column. If the answer is “no” enter “0” in the selection column. When all the questions have been answered and the selection column is completed, add up the total for the selection column. The total is the Software Setup Factor.

A.4 Recipe Formulas

The following formulas can be used to determine if a recipe is appropriate or possible.

Injection Molding

For injection molding applications, compute the dosing disc speed and total number of disc revolutions using the following formulas. Recipe limitations are listed in the table following the equations.

Disc RPM =

(Shot Weight - g) x (Additive - %) x 0.6

(Disc Calibration Weight - g) x (Recovery Time - s)

Disc Revolutions per Shot = (Shot Weight - g) x (Additive - %) x 0.01 (Disc Calibration Weight - g)

Recipe Limitations for Injection Molding

Motor Assembly Speed (rpm)

 

Maximum

 

Speed (rpm)

 

Number of Disc Revolutions

11.5

11.5

 

4.6

35.5

35.5

 

14.8

Digital Dosing Units

56

Page 56
Image 56
Sterling Plumbing 882 00276.00 specifications Determining the Software Setup Factor, Recipe Formulas, Injection Molding