3.5 Extrusion – Proportional (Extruder Follower Option)

Recipe Input – Extrusion Proportional

To enter a recipe for Extrusion Proportional, the following process data is required:

Percentage of additive

Expected throughput of the extruder during production

Extruder screw speed during production

Calibration weight in grams

Step 1:

Press the Input key, , once.

The symbol flashes.

After “1” flashes quickly on the display, a number in the format xxx.xx will come up on the display.

Enter the additive percentage by using the Arrow Keys . The range of values that can be entered is 0.01% to 50.00%. The arrow keys are used to change all process variables. The double arrow key allows the user to ramp up or down at a faster rate.

Step 2:

or

Press again.

The machine displays a flashing “g” or “lb”, a flashing “min” and .

Digital Dosing Units

34