Step 7:

Press a fifth time to return to the totalizer.

Operation – Extrusion – Proportional (Extruder Follower Option)

;Ensure that the unit is properly installed (Section 3.1)

;A recipe is entered (“Recipe Input-Extrusion Proportional” Section )

;The feeder is calibrated (Section 3.6), before attempting to begin operations.

1.If desired, clear the totalizer by pressing continuously for 5 seconds until the display is reset to “00.00.”

2.Place the Digital Dosing unit into operation by pressing the Run key (). The green LED will light when the unit is ready to dose, but will not feed until the extruder begins operation.

3.Start the extruder. The Digital Dosing unit will begin dosing material as soon as the extruder starts. If the unit is installed properly, the process machine symbol will light on the controller when the extruder starts. The disc symbol will light when the Digital Dosing is dosing material

4.To stop the dosing process while the extruder is operating, press . The Digital Dosing unit will automatically stop dosing when the extruder stops.

5.While the unit is dosing, depending on software revision, the current recipe can

be viewed but not modified, by pressing . In some software versions, the percent additive can be changed while the unit is dosing. The actual extruder screw speed will be displayed in the third recipe register.

Digital Dosing Units

37

Page 37
Image 37