Sterling Plumbing 882 00276.00 Initial Operation, Signal Converter with DC Power Supply

Models: 882 00276.00

1 79
Download 79 pages 6.69 Kb
Page 23
Image 23

Signal Converter with DC Power Supply

This module requires a separate 24 VDC power supply.

Vendor:

Phoenix Contact

Order Designation:

MCR-FL-C-UI-2UI-DCI-NC

Supply Voltage:

20 to 30V

DC

Input 4-20 mA, 0-10V (Quantity: 1)

Output 0-20 mA, 0-10V

(Quantity: 2)

24 VDC Mini Power Supply

A Phoenix Contact power supply for the Phoenix Contact signal conditioner listed above.

Vendor:

Phoenix Contact

Order Designation:

MINI-PS-100-240AC/24DC/1

Please note that the data given here has been taken from Phoenix Contact's online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com.

3.2 Initial Operation

The control system is factory-programmed. Nevertheless, specific values need to be predefined or checked prior to operation (basic parameter settings). The input values will be saved and will still be available if the unit is switched off, or a power failure occurs. Please refer to Appendix B for these values. Extrusion operations require a “span factor” to be entered into the basic settings. Please refer to Appendix B.

Prior to putting your new Digital Dosing Additive Feeder on-line:

You must enter a recipe and calibrate the feeder.

Recipe parameters are different for Injection Molding, Extrusion - Constant, and Extrusion - Proportional operation. See each individual section for details.

The calibration method is the same for all processes.

Once the unit is online, recipes can be saved for later recall (10 maximum).

Digital Dosing Units

23

Page 23
Image 23
Sterling Plumbing 882 00276.00 Initial Operation, Signal Converter with DC Power Supply, VDC Mini Power Supply