Operation - Injection Molding

1.Ensure that the unit is properly installed (Section 3.1), a recipe is entered (section 3.3.1), and the feeder is calibrated (Section 3.6), before attempting to begin operation.

2.If desired, clear the totalizer by holding the Stop key () continuously for five seconds until the display is reset to “00.00.”

3.Place the Digital Dosing feeder into operation by pressing the Run key (). The green LED will light when the unit is ready to dose.

or

Start the molding machine. The Digital Dosing feeder will not dose material until the molding machine screw recovers. If the unit is installed properly, the process machine symbol will light on the controller during screw recovery. The disc symbol will light when the Digital Dosing unit is dosing material.

The totalizer will increase after each cycle by the amount of material dosed.