Recipe Setup for Injection Molding:

1.Turn power switch to ON position.

2.Press Input to display # 1, “Additive %”. Using arrow keys, set additive ratio.

3.Press Input to display #2, “Shot size of current mold”. Using arrow keys, set the total shot size (parts and runners) of the current mold capacity in grams/pounds.

4.Press Input to display # 3, “Screw recovery time”. Using arrow keys, set the screw recovery time (in seconds).

5.Press Input to display # 4, “Calibration weight for additive”. Enter the appropriate value from the range table below and proceed to calibration mode below for calibration of additive material.

DD Discs

 

 

Disc

 

Calibration Number

 

 

 

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

DD 30-030672

1.75

 

 

 

 

 

 

 

 

 

 

 

 

DD 30-051040

5.00

 

 

 

 

 

 

 

 

 

 

 

 

DD 30-051725

8.00

 

 

 

 

 

 

 

 

 

 

 

 

DD 30-051818

15.00

 

 

DT Discs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disc

Calibration Number

 

 

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

DT 30-101820

32.00

 

 

 

 

 

 

 

 

 

 

 

 

DT 30-102025

38.00

 

DP Discs

 

 

 

 

 

 

 

 

 

DT 30-203012

100.00

 

 

 

 

 

 

 

Disc

Calibration Number

 

 

 

 

 

DT 30-204010

175.00

 

 

 

 

Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DP 30-050940

17.00

 

 

 

 

 

 

 

 

 

 

 

 

DP 30-250940

8.00

 

 

 

 

 

 

 

 

Digital Dosing Units

9