Operation – Extrusion - Constant

1.Ensure that the unit is properly installed (Section 3.1), a recipe is entered (Section 3.4.1), and the feeder is calibrated (Section 3.6), before attempting to begin operation.

2.If desired, clear the totalizer by pressing continuously for 5 seconds until the display is reset to “00.00.”

3.Place the Digital Dosing unit into operation by pressing . The green LED will light when the unit is ready to dose, but the Digital Dosing unit will not feed until the extruder begins operation.

4.Start the extruder. The Digital Dosing unit will begin dosing material as soon as the extruder starts. If the unit is installed properly, the process machine symbol will light on the controller when the extruder starts. The disc symbol will light when the Digital Dosing unit is dosing material.

5.To stop the dosing process while the extruder is operating, press . The Digital Dosing unit will automatically stop dosing when the extruder stops.

6.While the unit is dosing, depending on software revision, the current recipe can be

viewed but not modified, by pressing . In some software versions, the percent additive can be changed while the unit is dosing.

NOTE: See Appendix A, Troubleshooting, for information on problems or errors encountered and their resolution.