4.4Optional Equipment, Level Switches and Communications Options

Optional equipment for the Digital Dosing Additive Feeder includes:

Alarms

Several alarm options are available for the Digital Dosing feeder. The standard unit comes

with a flashing alarm symbol on the faceplate. Options include both audible horns and flashing lights. An optional no voltage alarm relay can be connected to the user’s central alarm system.

Level switches (probes)

To adjust the level switches:

1.Turn the controller ON.

2.Fill the dosing station until the level sensor is one-third covered.

3.Remove the small plastic screw (M3) on the back of the level sensor (see Figure 7).

LED Yellow (Station)

LED Green (Level Probe)

 

 

 

 

 

 

on: Station Filled

on: Power Supply Available

 

 

 

 

 

 

off: Station Emptied

off: Power Supply Not Available

 

 

 

 

 

 

 

npn: Normally Closed

 

 

 

 

 

npn: Normally Open

 

pnp: Normally Open 1

 

 

 

 

0 pnp: Normally Closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blind Lid

Trim-pot with

Protective Screw

Plastic Screw M3

Cable

 

Level Probe

Figure 7. Level Sensor Screw

4.Turn the trim-pot until the yellow control lamp just switches off.

Digital Dosing Units

44

Page 44
Image 44
Sterling Plumbing 882 00276.00 specifications Alarms, Level switches probes