Frequency [Hz] = Input current [mA] x 10000 [Hz] 20 [mA]

Note the data:

Min. input frequency = __________ Hz

Max. input frequency = __________ Hz

Calculate the span factor using the formula:

Span factor [Hz / rpm] =

 

Frequency [Hz]____________

 

 

Rotational speed of the extruder [rpm]x 10

 

Note the data:

 

 

 

Span factor = __________

 

 

 

Determining the Configuration Value

Extrusion (Constant or Proportional):

Mark the functions required. Use the numerical value indicated and insert it in the empty field

if applicable. Total the figures for configuration value.

 

 

Optional raw material level probe installed

. . ................ . . . . . . . . . . . . . . . . .

..1

___

Optional additive level probe installed . . . .

. . . . . . . . . ................ . . . . . . . . . ..

2

___

Optional blending unit installed

. . . . . . . . . . . . . . . . . ............... . ..

8

___

Totalizer displayed in lb (kg default)

. . . . . . . . . . . . . . . . . . . ................

16

___

Extruder throughput

(1 kg-6.5 Kg/min) . . .

. . .(2.2 lbs/min-14.3 lbs/min) ……..0

___

Extruder throughput

(10 kg-65 kg/min)……….(22 lbs/min-143 lbs/min)

32

___

Extruder throughput

(0.1 kg-0.65 Kg/min)

. . .(0.22 lbs/min-1.43 lbs/min)…....128

___

(NOTE: the throughput selections determine placement of the decimal point on the display)

External run/stop signal controls dosing

. . .............. . 64

___

Mounting on Micro mixing hopper

. . ............... . 256

. ___

Alarm output is switched in case of power failure

512

___

Extrusion proportional . . .

(extruder follower)

. . ............ . 1024

_____

Extrusion Constant ………………….……………………………………........…3072______

Printer available

.........16348

____

Configuration value:

_____

Example:

Level probes: raw material and additive probes installed

Digital Dosing Units

59

Page 59
Image 59