TANDBERG 880 MXP Gatekeeper Discovery Auto, Gatekeeper IP Address, Authentication Mode Auto

Models: 770 MXP 990 MXP 880 MXP

1 317
Download 317 pages 7.21 Kb
Page 214
Image 214

TANDBERG 770/880/990 MXP

Gatekeeper Settings

Gatekeeper Discovery

 

Auto

 

The system will automatically try to register to any available gatekeeper. If a

 

 

 

 

gatekeeper responds to the request sent from the codec within 30 seconds this

 

 

 

 

specific gatekeeper will be used. This requires auto discovery on the gatekeeper

 

 

 

 

as well. If no gatekeeper responds, the system will not use a gatekeeper for

 

 

 

 

making H.323 calls and hence an IP-address must be specified manually.

 

 

 

 

 

 

 

 

 

 

 

 

Manual

 

The system will use a specific gatekeeper identified by Gatekeeper IP-address.

 

 

 

 

 

 

Gatekeeper IP Address

This is the gatekeeper IP-address that is used if you specify H.323 Call Setup: Gatekeeper and

Gatekeeper Discovery: Manual.

Note that if your system is part of a TANDBERG Expressway™ firewall traversal solution and is placed outside the firewall, you should register the IP address of your Border Controller as the Gatekeeper IP address and set H.323 Call Setup to Gatekeeper.

Authentication Mode

 

Auto

 

If Authentication Mode is set to Auto and the gatekeeper indicates that it requires

 

 

 

 

authentication, the endpoint will automatically try to authenticate itself to the

 

 

 

 

Gatekeeper.

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

If Authentication Mode is set to Off the system will not try to authenticate itself to a

 

 

 

 

Gatekeeper, but will still try a normal registration.

 

 

 

 

 

 

Authentication ID / Authentication Password

The system sends the Authentication ID and Password to a Gatekeeper for authentication. The authentication is a one way authentication from the endpoint system to a Gatekeeper, i.e. the endpoint is authenticated to the Gatekeeper. If the Gatekeeper indicates that no authentication is required, the endpoint will still try to register.

Multiple H323 Aliases

 

On

 

If set to On, the system will register multiple H.323-IDs on the Gatekeeper based on

 

 

 

 

the values of the parameters: System Name, International Name and H.323 ID.

 

 

 

 

Up to 3 aliases are possible.

 

 

 

 

 

 

 

 

 

 

 

 

Off

 

If all fields are empty, the System Name is set to TANDBERG-<serial no> and

 

200