TANDBERG 990 MXP, 880 MXP, 770 MXP LOS a RS366 DPR RS366 ACR RS366 CRQ RS366 PND RS366 DLO

Models: 770 MXP 990 MXP 880 MXP

1 317
Download 317 pages 7.21 Kb
Page 303
Image 303

Appendices

Cable Specification

RS-449/RS-366 Cable

TANDBERG MXP and Classic Endpoints that support External Network

Connector on Tandberg End:

oFemale 26pin High Density DSUB Newark P/N 50F2055 or Equivalent

Connector on RS-449:

oDSUB 37 pin Male

Connector on RS-366:

oDSUB 25 pin Male

Signal Name

Female

Male

Male

 

26pin DSUB

37pin DSUB

25pin DSUB

 

(Tandberg

(DCE end)

RS-366

 

end)

Pin Number

Pin Number

 

Pin Number

 

 

Frame Ground

1

1

 

Signal Ground

19

19,30

 

Send Data (A)

11

4

 

Send Data (B)

12

22

 

Send Timing (A)

17

5

 

Send Timing (B)

18

23

 

Receive Data (A)

13

6

 

Receive Data (B)

14

24

 

Receive Timing(A)

15

8

 

Receive Timing (B)

16

26

 

Terminal Ready(A)

26

12

 

Receiver Ready (A)

22

13

 

Receiver Ready (B)

23

31

 

Incoming Call (A)

24

15

 

LOS A

25

36

 

RS366 DPR

2

 

2

RS366 ACR

3

 

3

RS366 CRQ

4

 

4

RS366 PND

5

 

5

RS366 DLO

6

 

22

RS366 NB1

7

 

14

RS366 NB2

8

 

15

RS366 NB4

9

 

16

RS366 NB8

10

 

17

RS366 DSC

20

 

13

RS366 PWI

20

 

6

RS366 GND

1

 

7

Comments

Do not connect shield to FGND

Twisted Pair

Twisted Pair

Twisted Pair

Twisted Pair

Twisted Pair

LOS A Unbalanced

289

Page 303