TANDBERG 770/880/990 MXP
6.1.4Data port
The data port(s) are implemented as Data Communications Equipment (DCE). The connectors used are female
|
| Signal name |
|
| Direction |
| Pin number |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Carrier detect, CD |
|
| From DCE |
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Receive data, RXD |
|
| From DCE |
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Transmit data, TXD |
|
| To DCE |
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Data terminal ready, DTR |
|
| From DCE |
| 4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Signal ground, GND |
|
|
|
| 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Data set ready, DSR |
|
| From DCE |
| 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ready to send, RTS |
|
| To DCE |
| 7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Clear to send, CTS |
|
| From DCE |
| 8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ring indicator, RI |
|
| From DCE | 9 |
|
|
226