Dynamic Bandwidth adjustments (H.323)

NETWORK FEATURES Auto H.320/H.323 dialing

SIP Downspeeding Programmable network profiles Intelligent Call Management Maximum call length timer

Automatic SPID and line number configuration (National ISDN, GR-2941-CORE)

SoftMux

H.331 Broadcast Mode

NATO standard KG194/KIV-7 encryptor support** URI Dialing

MULTISITE FEATURES (990 & 880 MXP ONLY) H.323/H.320/SIP/Telephony/VoIP in the same conference Audio and Video Transcoding Video rate matching from 56 kbps - maximum conference rate CP4 and Voice Switched

Best Impression (Automatic CP Layouts) H.264, Encryption, Digital Clarity

Dual Stream from any site

ISDN & IP Downspeeding and IPLR

MultiSite (H.243) Cascading on H.320 & H.323 Unicode H.243 Terminal Names

Dial in/Dial out

Chair control for host system

Snapshot of ongoing conference (JPEG) Snapshot of ongoing DuoVideo/H.239 presentation (JPEG)

Separate welcome page for encrypted conferences Conference rates up to 2.3 Mbps with optional bandwidth

upgrade (1.5 Mbps is standard conference rate) Up to 4 video and 3 audio sites

4 sites @ 768 kbps (+telephone calls)

Mix ISDN-BRI and IP up to maximum conference rate

EMBEDDED ENCRYPTION

H.320 and H.323 point-to-point and multipoint calls Standards-based: H.233, H.234, H.235 v2&v3, DES and

AES NIST-validated AES NIST-validated DES

Automatic key generation and exchange Supported in Dual Stream & MultiSite

Editor

Import Custom Language through TMS

CUSTOMIZED WELCOME SCREEN AND COMPANY LOGO

Picture JPEG (logo.jpg): Recommended maximum size is 704x576 for Welcome Screen and 352x288 for Encryption Required Screen.

POWER

Auto-sensing power supply 100 – 250 VAC, 50 – 60 Hz 40 watts max.

OPERATING TEMPERATURE AND HUMIDITY 0° C to 35° C (32° F to 95° F) ambient temperature 10% to 90% Relative Humidity (RH)

STORAGE AND TRANSPORT TEMPERATURE

-20° C to 60° C (-4° F to 140° F) at RH 10-90% (non- condensing)

APPROVALS

Directive 73/23/EEC (Low Voltage Directive) - Standard EN 60950

Directive 89/336/EEC (EMC Directive)

-Standard EN 55022, Class B

-Standard EN 55024

-Standard EN 61000-3-2/-3-3

Directive 1999/5/EEC (R&TTE Directive) - Standard TBR3

Approved according to UL 60950 and CAN/CSA C22.2 No.60950

Complies with FCC15B Class B

UNIT DIMENSIONS

Height: 5.1"/13.0 cm

Width: 14.9"/38.0 cm

Depth: 7.9"/20.0 cm

Weight: 5.0 lbs/2.3 kg

Weight: 5.0 lbs/2.3 kg

PRODUCT RELIABILITY / MTBF

The predicted reliability is expressed in the expected random Mean Time Between Failures (MTBF) for the electronic components based on the Power On Hours:

Power On Hours (POH) > 69 000 hours Useful Life Cycle > 6 years

ISO 9001 certificate is available upon request

*Requires TANDBERG Management Suite 9.0 or newer

**Optional equipment, must be specified at the time of order.

System features vary depending on network selection and software package. All specifications are subject to change without notice. TANDBERG is a registered trademark or trademark of TANDBERG in the U.S. and other countries. RealPlayer is a trademark or a registered trademark of RealNetworks, Inc. QuickTime is a registered trademark of Apple Computer, Inc., registered in the U.S. and other countries. Microsoft and NetMeeting are either registered trademarks or