5)Type in your IP password (default is “TANDBERG”) as password.
6)Type ‘put <software file name> and press Enter. The new software file will now be uploaded to the TANDBERG MXP system.
7)When the software upload is complete, end the ftp connection to the TANDBERG MXP system by typing ‘bye’ in the DOS prompt.
8)To exit the DOS window completely, type ‘exit’
9)Restart the system to activate the new software.
C)ISDN Upgrade
The TANDBERG MXP systems has the possibility to be upgraded remotely from another TANDBERG MXP system using ISDN. Please note that both systems must be on software version F3.0 or newer for this functionality.
Please also note that both systems must be on software version F3.0 or newer for this functionality
1.Connect to the system that shall be upgraded using ISDN
2.Copy the new software file to a folder on your computer, for instance c:\software.
3.Type the IP address of the TANDBERG MXP system that the software upgrade is going to be done from (for instance 10.0.8.77) in a standard browser, such as Internet Explorer 6.0. The web interface of the codec will then be displayed.
4.Select the ‘System Configuration’ tab on top of the page, and then the