Name

fan-state-notif

 

 

Description

 

The fan state has changed

Includes

 

Message

 

 

 

 

Fan State:

 

 

 

 

-1

notImplemented

This indicates there may be an SNMP reporting

 

 

 

 

 

problem

 

 

 

 

 

 

 

 

 

0

noState

N/A

 

 

 

1

error

One or more fan channels have stopped;

 

 

 

 

 

temperature warnings that will cause the system

 

 

 

 

 

to shutdown are imminent.

 

 

 

 

 

 

 

 

 

2

warn

Single fans in one or more fan channels have

 

 

 

 

 

stopped or are running slowly. There is no

 

 

 

 

 

immediate danger, but the fans may need to be

 

 

 

 

 

serviced.

 

 

 

 

 

 

 

 

 

3

good

All fans are working properly.

 

 

 

 

 

 

 

 

 

4

warnHigh

One or more fans are spinning too fast. The

 

 

 

 

 

system is in no immediate danger but may need

 

 

 

 

 

to be serviced.

 

 

 

 

 

 

 

 

 

5

errorHigh

N/A

 

 

 

6

noDevice

N/A

 

 

 

7

notMonitored

Fan monitoring has been turned off to suppress

 

 

 

 

 

warnings.

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

disk-state-notif

 

 

Description

 

The disk state has changed

Includes

 

Message

 

 

 

 

Device Number

 

 

 

 

Disk State:

 

 

 

 

-1

notImplemented

This indicates there may be an SNMP reporting

 

 

 

 

 

problem

 

 

 

 

 

 

 

 

 

0

noState

N/A

 

 

 

1

error

N/A

 

 

 

2

warn

N/A

 

 

 

3

good

The disk is working properly

 

 

 

 

 

 

 

 

 

4

warnHigh

The disk is rebuilding.

 

 

 

 

 

 

 

 

 

5

errorHigh

The disk has failed, or is missing from the system.

 

 

 

 

 

 

 

 

 

6

noDevice

N/A

 

 

 

7

notMonitored

Monitoring has been turned off to suppress

 

 

 

 

 

warnings.

 

 

 

 

 

 

 

 

 

 

 

 

 