6.4.2Via Text Management Linking Fibre Channel Controllers

From the Telnet Main Menu, select “LUN Setup

Select “Link/unlink fibre channel controller(s) to/from LUN(s)

Figure 6-8: Link LUNs Screen

The Link LUNs screen port above the menu. selected controller as

displays the currently selected controller and Figure 6-8: Link LUNs Screen displays the 2-A, which is Controller 2 Port A.

To change the selected controller select “Select different controller”. This displays a list of controllers. Select one and press [ENTER].

To change the port, select “Select different channel on controller”. This displays a list of channels. Select one and press [ENTER].

In addition, the “Link/Unlink LUN(s)” screen indicates the number of LUNs currently linked to the selected controller.

To link a LUN to the selected controller, select “Link LUN(s) to selected controller”.

From the sub-menu that lists all LUN numbers not already linked to another FC port, select a LUN number and press [ENTER].

If all LUNs are linked to ports already, then the system displays an error message.

Select “Exit to the LUN configuration menu

To save the changes once you have completed all LUN configuration, select “Save changes and exit

To ensure that your changes were successful, see Section 6.3 -

Viewing LUN Status / LUN Map.