E6581741

5.1.11. Instance 105: TOSHIBA specific output

Instance 105 mapping

 

 

 

Bit 3

 

 

 

 

Byte

Bit 7

Bit 6

Bit 5

 

Bit 4

 

Bit 2

Bit 1

Bit 0

0

 

 

 

Function code (Read / Write) (*1)

 

 

 

1

 

 

 

 

 

 

2

 

 

 

 

Index (Low byte)

 

 

 

3

 

 

 

 

Index (High byte)

 

 

 

4

 

 

 

 

Data (Low byte)

 

 

 

5

 

 

 

 

Data (High byte)

 

 

 

6

 

 

 

c001 Command data (Low byte)

 

 

 

7

 

 

 

c001 Command data (High byte)

 

 

 

8

 

 

 

c002 Command data (Low byte)

 

 

 

9

 

 

 

c002 Command data (High byte)

 

 

 

10

 

 

 

c003 Command data (Low byte)

 

 

 

11

 

 

 

c003 Command data (High byte)

 

 

 

12

 

 

 

c004 Command data (Low byte)

 

 

 

13

 

 

 

c004 Command data (High byte)

 

 

 

14

 

 

 

c005 Command data (Low byte)

 

 

 

15

 

 

 

c005 Command data (High byte)

 

 

 

16

 

 

 

c006 Command data (Low byte)

 

 

 

17

 

 

 

c006 Command data (High byte)

 

 

 

Refer to "Scanner Address (c001 – c006) and Scanner Value (c041 – c046: details of command data)."

5.1.12. Instance 155: TOSHIBA specific input

Instance 105 mapping

 

 

 

Bit 3

 

 

 

 

Byte

Bit 7

Bit 6

Bit 5

 

Bit 4

 

Bit 2

Bit 1

Bit 0

0

 

 

 

Function code (Read / Write) results

 

 

 

1

 

 

 

 

 

 

2

 

 

 

 

Index (Low byte)

 

 

 

3

 

 

 

 

Index (High byte)

 

 

 

4

 

 

 

 

Data (Low byte)

 

 

 

5

 

 

 

 

Data (High byte)

 

 

 

6

 

 

 

c021 Command data (Low byte)

 

 

 

7

 

 

 

c021 Command data (High byte)

 

 

 

8

 

 

 

c022 Command data (Low byte)

 

 

 

9

 

 

 

c022 Command data (High byte)

 

 

 

10

 

 

 

c023 Command data (Low byte)

 

 

 

11

 

 

 

c023 Command data (High byte)

 

 

 

12

 

 

 

c024 Command data (Low byte)

 

 

 

13

 

 

 

c024 Command data (High byte)

 

 

 

14

 

 

 

c025 Command data (Low byte)

 

 

 

15

 

 

 

c025 Command data (High byte)

 

 

 

16

 

 

 

c026 Command data (Low byte)

 

 

 

17

 

 

 

c026 Command data (High byte)

 

 

 

Refer to "Scanner Address (c021 – c026) and Scanner Value (c061 – c066: details of command data)."

(*1): Please set the function code as follow. Read: 0x00

Write: 0x80

- 52 -

Page 53
Image 53
Toshiba IPE002Z Instance 105 Toshiba specific output, Instance 155 Toshiba specific input, Instance 105 mapping Bit Byte