E6581741

 

 

 

 

 

 

 

 

Title

Communi

Function

 

 

Description

 

Factory

cation No.

 

 

 

setting

 

 

 

 

 

 

 

 

 

0:

-

(Status information 1)

 

1

 

 

 

1: fd01

 

 

 

 

 

2: fd00

(Output frequency, 0.01Hz)

 

 

 

 

 

3: fd03

(Output current, 0.01%)

 

 

 

 

 

4: fd05

(Output voltage, 0.01%)

 

 

 

 

 

5: fc91

(Alarm information)

 

 

 

 

 

6: fd22

(PID feedback value, 0.01Hz)

 

 

 

 

7: fd06

(Input terminal board status)

 

 

 

 

8: fd07

(Output terminal status)

 

 

 

 

 

9: fe36

(VIB input, 0.01%)

 

 

 

 

 

10: fe35

(VIA input, 0.01%)

 

 

 

 

 

11: fe37

(VIC input, 0.01%)

 

 

 

 

 

12: fd04

(Input voltage (DC detection), 0.01%)

 

 

 

 

13: fd16

(Estimated speed 0.01Hz)

 

 

 

 

 

14: fd18 (Torque, 0.01%)

 

 

 

 

 

15:

-

 

 

 

 

 

 

16:

-

 

 

 

c021

C021

Scanner output 1 address (*3)

17:

-

 

 

 

18:

-

 

 

 

 

 

 

 

 

 

 

 

 

19: f880

(Free notes)

 

 

 

 

 

20: fd29

(Input power, 0.01kW)

 

 

 

 

 

21: fd30

(Output power, 0.01kW)

 

 

 

 

 

22: fe14

(Cumulative operation time, hour)

 

 

 

 

23: fe40 (FM terminal output monitor, 0.01%)

 

 

 

 

24:

-

 

 

 

 

 

 

25: fd20 (Torque current, 0.01%)

 

 

 

 

 

26: fd23 (Motor overload factor, 0.01%)

 

 

 

 

27: fd24 (Drive overload factor, 0.01%)

 

 

 

 

28: fd25 (PBR overload factor, %)

 

 

 

 

 

29: fd26 (Motor load factor, %)

 

 

 

 

 

30: fd27 (Drive load factor, %)

 

 

 

 

 

31: fe56 (Pulse train input, pps)

 

 

 

 

 

32: fe70 (Drive rated current, 0.1A)

 

 

 

 

 

33: fe76 (Input Watt-hour, 0.1kWh

10f749)

 

 

 

 

34: fe77 (Output Watt-hour, 0.1kWh

10f749)

 

 

 

 

35: fd83 (IGBT temperature, degree C)

 

c022

C022

Scanner output 2 address (*3)

0-35 (Same as c021)

 

2

c023

C023

Scanner output 3 address (*3)

0-35 (Same as c021)

 

0

c024

C024

Scanner output 4 address (*3)

0-35 (Same as c021)

 

0

c025

C025

Scanner output 5 address (*3)

0-35 (Same as c021)

 

0

c026

C026

Scanner output 6 address (*3)

0-35 (Same as c021)

 

0

 

 

 

16 characters

 

 

c081-

C081-

 

The

device

name is required if the

card uses

0,0,0,0,

c096

C096

Device Name 1-16 (*4)

DHCP to obtain its IP Address.

 

0,0,0,0

Refer to "3.2.1 Device name (c081-c096) for the

 

 

 

 

 

 

 

details.

 

 

 

c100

C100

Communication error

0.0 - 100.0 sec.

 

0.0

detection delay time

 

 

 

 

 

 

 

 

 

 

 

0: Stop and controlled by cmod, fmod

 

 

 

 

1: Operation continue

 

 

 

C101

Inverter operation at the

2: Deceleration stop

 

4

c101

3: Coast stop

 

communication loss action

 

 

 

4: Network error stop (err8 trip)

 

 

 

 

 

 

 

 

 

 

5: Preset speed operation (by c102 setting)

 

 

 

 

 

 

 

 

c102

C102

Preset speed operation

0: None

 

 

0

selection

1 to 15: Preset speed

 

 

 

 

 

 

 

 

 

0: Disconnection detection

 

0

 

 

Communication time-out

1:

When communication mode enable (Both

 

c103

C103

cmod

and fmod are set CANopen or

 

condition selection

 

 

 

communication option) only

 

 

 

 

 

 

 

 

 

 

2: 1 + Driving operation

 

 

(*3): This parameter is effective by reset. Please reset (power supply reset or f899=1) after changing a set point.

(*4): (V[R) does not work for this parameter.

- 8 -

Page 9
Image 9
Toshiba IPE002Z instruction manual 0,0