5. READ (X) AND RESET (Z) REPORTS

EO1-11110

5.1 Combination Reports

5.1Combination Reports

Multiple reports can be programmed to be issued in one operation sequence. The following are reports programmable for combinations (max. 5 reports in one table, max. 3 tables). Ask your TOSHIBA TEC representative for information of the contents of your Combination Report Tables or for changes.

REPORT NAME

 

AVAILABLE REPORTS

Financial Report

X

Z

GTX

GTZ

All Cashier Report

X

Z

GTX

GTZ

All Salesperson Report

X

Z

 

 

Credit Company Sales Report

X

Z

GTX

GTZ

Department Group Report

X

 

GTX

 

Media Sales and In-drawer Report

X

 

 

 

Hourly Range Report

X

Z

 

 

All Department Report

X

Z

GTX

GTZ

All Media Sales & Cash-in-drawer Report

X

 

 

 

All PLU Report

X

Z

GTX

GTZ

All Customer Files Report

X

 

 

 

PLU Group Sales Report

X

Z

GTX

GTZ

KEY OPERATION: Mode Lock: X for Read Z for Reset

[AT/TL]

Enter the Report Combination-ID No.:

None (simply depress [AT/TL]): Daily Combination Report Table No.1

200: GT Combination Report Table No.1

1:Daily Combination Report Table No.2

201: GT Combination Report Table No.2

2:Daily Combination Report Table No.3

202: GT Combination Report Table No.3

NOTES: 1. When the mode set for taking combination reports does not match the mode of a report contained in the table, that report will be skipped.

2.If no combination reports data have been programmed, Combination Report Table No. 1 (which is issued by depressing the [AT/TL] key alone for Daily Reports and depressing 200 [AT/TL] for GT Reports) is auto-preset with All Department Report and Financial Report. It will be active as Table No. 1 content unless no data are programmed for Table No. 1.

3.The report output order is determined by the order programmed in each table.

4.The drawer will open when a contained report is ruled to open the drawer.

5.2GENERAL NOTES ON REPORT TAKINGS

1.The cashier signed-OFF or signed-OUT condition is required for taking any Z reports in the Code Entry Method. (Otherwise, an error will result when the Mode Lock is turned to the “X” or “Z” position.) However, in case of a standalone system with PC connected and CVS spec. selected, X/Z reports can be taken during sign-ON and sales entries.

2.Reset reports will be printed on the receipt roll as well as on journal, and issued, regardless of the current Receipt-ON/OFF status.

3.The [ITEM CORR] (or [VOID]) key may be depressed halfway during printing a report, for the purpose to abort the receipt issuance (except for some short reports). When a report-abort has been operated for a reset report, the memory of the report data will not be cleared.

5-4