7.3 PLU PRICE CHANGE WITH DLL (Submode 73)

7.3PLU PRICE CHANGE WITH DLL (Submode 73)

This submode is used to change prices of PLUs existent in the PLU files, and to immediately load the data into Satellite Terminals.

CONDITION

Any time outside a sale for Master or Satellite

 

(when the feature “PLU not to be inquired” is selected)

 

Anytime outside a sale for Master (When the feature “PLU to be inquired” is selected)

OPERATION

Mode Lock: SET and IN-LINE Lamp illuminated

Barcode Scanning

73 [@/FOR] PLU Code [PLU]

Can be skipped (for non-Split Pricing type or when Whole Package Quantity is 1)

New Whole Package Quantity [ST]

Repeat for other PLUs.

*

 

 

New Preset Price

 

 

 

[#]

 

 

[AT/TL]

 

 

 

 

 

 

 

 

 

 

Max.6 digits

 

 

 

 

 

(NOTE 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to make open-price PLU

 

 

 

 

 

 

 

 

 

 

* (Repeatable from here for sequentially programming PLU Codes.)

 

 

 

 

NOTES: 1. When the [AT/TL] key is depressed in the above operation, it sends a DLL-start command to the designated terminals, makes the terminals in HOLD condition, and executes DLL. After DLL is completed, it sends a DLL-end command to each terminal and releases the HOLD condition.

2.A maximum of 100 PLUs’ prices can be changed in one operation sequence of this submode.

3.When zero is entered as the New Preset Price value, the PLU is set with a zero price. When the New Preset Price entry is skipped and the [#] is simply depressed, it will be an open-price PLU.