4. ADDITIONAL FUNCTION KEY AND REGISTERING PROCEDURE

EO1-11110

4. ADDITIONAL FUNCTION KEY AND REGISTERING PROCEDURE

4.ADDITIONAL FUNCTION KEY AND REGISTERING PROCEDURE

The following is the key that can be installed on the Master Terminal of an in-line system, in addition to the standalone specifications, and the registering procedure using the key.

RTR (Register-to-Register) DECLARATION Key ([RTR])

By depressing the [RTR] key on the Master Terminal, various in-line jobs (DLLs, Consolidated Read/Reset Report takings, etc.) can be performed.

PROCEDURE ON A MASTER TERMINAL FOR RTR DECLARATION

Mode Lock: SET, X, Z, or MGR/Anytime outside a sale

Depress [RTR]

NOTES:

1.

While a PC job is under way ( a command of ULL, DLL, or Read/Reset from the PC), this RTR

 

 

Declaration is not possible. Similarly, while this RTR Declaration is on, no PC jobs are possible.

 

2.

While the RTR Declaration is on, no transaction entries in REG, MGR, or - mode are possible.

3.While the RTR Declaration is on, no Backup Data Check is performed.

4.While the RTR Declaration is on, the following are jobs to be allowed:

Programming Operations

DLL Operations (DLL to Satellite Terminals)

Consolidated Read/Reset Report takings

Manual Copying of Backup Data

5.The [RTR] key can be programmed to require Manager Intervention.

6.If the option “Auto Data Copying feature” is selected for Copying of Backup Data, the RTR Declaration is not possible while a backup data update process is under way.

7.If the option “Compulsion of Data Sending to PC” is selected, the RTR Declaration is not possible until sending the reset data (the consolidation data) to PC is completed.

By depressing the [RTR] key on the Master Terminal when the RTR Declaration is on, the RTR Declaration ON status is canceled.

PROCEDURE ON A MASTER TERMINAL FOR RTR DECLARATION CANCEL

Mode Lock: SET, X, Z, or MGR/RTR Declaration is ON

Depress [RTR]

NOTE: If the Backup Error Flag is ON (the standard error message is “PLEASE BACK UP”), it means that manual copying of Backup Data is required, and therefore the RTR Declaration Cancel is not accepted until copying is completed.