9. BACKUP FUNCTION

EO1-11110

9. BACKUP FUNCTION

9.BACKUP FUNCTION

(ONLY WHEN THE BACKUP MASTER IS CONNECTED)

(1)Function

By connecting the backup master terminal (BM), the various files stored in the master terminal (M) can be backed up.

The terminal assigned to ID No. 2 will function as a backup master terminal (BM). By programming ID No. 2 in the terminal connection table and downloading this data to each terminal, the system will function as a system in which the backup master terminal (BM) is connected.

By changing terminal ID from 2 to 1, the backup master terminal (BM) will function as the master terminal (M).

<Files to be Backed Up>

PLU Main Table

Program data

(When the PLU inquiry function is used)

Sales data

PLU Additional Table

Program data

(When the PLU inquiry function is used)

Sales data

Link PLU Table

Program data

(When the PLU inquiry function is used)

 

Cashier Table

Program data

(When the floating cashier system is used)

Sales data

Customer File (Check Track) Table

Program data

 

Sales data

Negative Code Table

Program data

PC Transmission Information Table

Program data

NOTES: 1. Data capture (DC) transaction files are not backed up.

2.The tables (center files) managed by the master terminal (M) and used by each terminal via inquiries and PC transmission information tables are backed up.

Sales data is backed up on a real-time basis.

When sales data of the master terminal (M) is updated, sales data of the backup master terminal (BM) is updated at the same time.

Backup data check function:

Correspondence between the center files and backup data is checked every certain period of time.

Backup data update process:

When an error occurs in backup data, the following processing methods can be selected according to the program option setting.

(1)Automatic data copy

When the version of the center file stored in the master terminal (M) is different from that stored in the backup master terminal (BM), registration jobs are automatically prohibited, the backup data is properly exchanged.

While updating the backup data, each inquiry from the terminals may result in a “MASTER IS BUSY” error.

(2)Manual data copy

When the version of the center file stored in the master terminal (M) is different from that of data stored in the backup master terminal (BM), the master terminal (M) gives a short beep at the timing of issuing the long receipt to warn that the data is not backed up properly.

The operator should update the backup data manually.

9-1