5. PROGRAMMING OPERATIONS

EO1-11110

5.2PROGRAMMING OPERATIONS ADDED FOR IN-LINE TERMINALS

5.2PROGRAMMING OPERATIONS ADDED FOR IN-LINE TERMINALS

5.2.1TERMINAL CONNECTION TABLE SETTING (Submode 69; added for Master Terminal only)

This submode is required for in-line services. Enter the In-line ID No. and the Register No. of each terminal (including the Master Terminal) connected to the in-line cable.

CONDITION

 

Any time outside a sale

 

 

 

OPERATION

 

Mode Lock: SET and IN-LINE Lamp illuminated

69 [@/FOR]

 

 

In-line ID No. [ST]

 

 

Register No. [#]

 

 

 

 

 

 

. . .

 

 

. . .

 

 

 

1 to 16

*

 

0 to 999999

 

 

(NOTES 1 & 2 below)

 

 

(NOTE 2 below)

 

 

 

 

 

 

 

[AT/TL]

*For sequentially programming In-line ID Nos., the In-line ID specification can be skipped.

Repeat for other terminals to be connected, including the Master Terminal itself. (Max. 16 terminals for the Scanning System Type or PLU Manual Entry System Type, including the Master Terminal.)

NOTES:

1. In-line ID No.: Master Terminal

1 (fixed)

 

Backup Master Terminal (if connected)

2 (fixed)

 

Satellite Terminals

3 to 16 (max.14 terminals)

2.The In-line ID No. and Register No. of each terminal to be set here must be the same as those programmed for the terminal in IN-LINE TERMINAL ID SETTING (Submode 77) and STORE/ REGISTER NO. SETTING (no submode) in Chapter 6 in the Manager’s Guide for stand-alone level.

3.To delete an individual terminal from the Terminal Connection Table, enter 0 in place of the In- line ID No. in the above operation pattern.

4.To delete the entire Terminal Connection Table once set, operate:

69[@/FOR] 0 [AT/TL]

5.If a deleting operation (individual or entire deletion) is performed, the files occupied by the deleted terminal(s) (such as Floating Cashier File, etc.) is canceled.

Therefore, a deleting operation should be performed only when the system is to be re-built or a terminal is to be detached from the system.

ex.) To set a Master Terminal and a Satellite Terminal in the connection table (total of two terminals in the in-line system):

Master Terminal

ID No.1

Register No.111101

Satellite Terminal

ID No.3

Register No.333303

Mode Lock: SET/ and IN-LINE Lamp illuminated

69[@/FOR]

1 [ST] 111101 [#] (for the Master Terminal)

3 [ST] 333303 [#] (for the Satellite Terminal)

[AT/TL]

TEC STORE

1343 PEACH DRIVE PHONE : 87-6437

Open 8:00am to 7:00pm Closed: every Wednesday

19-12-1994 MON #1

P69

01#111101

03#333303

0014 14:21TM

5-2