10. REGISTERING PROCEDURE AND PRINT FORMAT

EO1-11110

 

10.31 SCALE ENTRY

 

10.31 SCALE ENTRY

OPERATION

(The department or PLU through which scale items are entered must be a Scale-Allow

 

department or a Scale-Compulsory PLU)

(1)Auto Scale Entry (without tare/tare 2/tare 3, or with tare/tare 2/tare 3 auto-subtraction)

(M)

Through Dept: Place the item [SCALE] Unit Weight [@/FOR]

on the scale platter.

 

1 to 9 (LB or Kg), 10 for 1/2 LB

For entry with General Weight Unit

.....

or 100g, 11 for 1/4LB (when the

 

Unit Weight is different from the

 

 

 

 

General Weight Unit)

Unit Price [Open DEPT] - - -

per Unit Weight

Open-Dept Code [DP#] Unit Price [AMT]

per Unit Weight

Through Preset-PLU: Place the item on the ([SCALE])

scale platter.

 

Preset PLU Code [PLU]

 

- - -

 

([SCALE])

 

 

 

• Through Open-PLU: Place the item on the

 

 

 

scale platter.

 

 

 

Open PLU Code [PLU] Unit Price [AMT] - - -

per Unit Weight

(M)

(M)

NOTES: 1. When the PLU is programmed with a Tare Table No., the tare weight is automatically subtracted from the scaled weight, and thus only the net weight is processed.

2.If the Tare 2 rate is programmed in the PLU table, a Tare 2 entry is performed when the above Preset/Open PLU entry is performed.

(2)Auto Scale with Tare/Tare 2/Tare 3

Tare Table No. [TARE] to be continued to the arrows marked with “(M)” in the above three

1 to 9

 

operation sequences of the Auto Scale Entry.

Tare Table No. [TARE]

 

Tare 2 Rate [TARE 2]

 

to be continued to the arrows

 

 

1 to 9

 

0 to 99.99 (%)

 

marked with “(M)” in the above

 

 

 

 

three operation sequences of the

 

 

 

 

Auto Scale Entry.

Tare 2 Rate [TARE 2]

0 to 99.99 (%)

Tare Weight [TARE 3]

Any value other than 0, however, less than the weight of scaled item

to be continued to the arrows marked with “(M)” in the above three operation sequences of the Auto Scale Entry.

to be continued to the arrows marked with “(M)” in the above three operation sequences of the Auto Scale Entry.

10-22