Toshiba MA-1650-4 owner manual Customer File Read, # → File Code @/FOR → AT/TL

Models: MA-1650-4

1 228
Download 228 pages 41.87 Kb
Page 202
Image 202

4. READ AND RESET REPORTS

EO1-11110

4.2 IN-LINE REPORTS

TABLE OF IN-LINE REPORT OPERATIONS (continued)

RTR Declaration: ON

 

Report Name

Mode

 

 

Key Operation

 

 

Lock

 

 

 

 

 

 

 

 

CUSTOMER FILE READ

 

 

 

 

(for Check Track Memory type only)

 

 

 

 

All Files Read

X

15

[AT/TL]

 

All Files Reset

Z

 

 

[#] Zone-start File Code

Zone Files Read

X

15

Zone Files Reset

Z

[@/FOR] Zone-end File Code [AT/TL]

Individual File Read

X

15

[#] File Code [@/FOR] [AT/TL]

Zero-balance Files Read

X

15 [#] 0

[AT/TL]

Credit-balance Files Read

X

15 [#] 1

[AT/TL]

Debit-balance Files Read

X

15

[#] 2

[AT/TL]

NOTE: When the “Process Report” is marked, the report can only be taken after taking another report which consolidates the corresponding data to be based on. For further details, see the table and descriptions below.

PROCESS REPORTS AND BASE REPORT DATA

The following table shows which process reports are available after which report data collections.

Reports Collection Required before Process

 

Report takings

Process Reports available

(CONSOLIDATION MEMORY CAPTURE: NOTE 1)

 

 

 

All Department Read Daily

Individual Department Read Daily

or

 

All Department Reset Daily

 

All Department Read GT

Individual Department Read GT

or

 

All Department Reset GT

 

Any of the following PLU reports (NOTE2)

Individual PLU Read Daily

 

Inactive PLU Read Daily

All PLU Read Daily

 

Zone PLU Read Daily

 

All PLU Reset Daily

 

Zone PLU Reset Daily

 

Any of the following PLU reports (NOTE2)

Individual PLU Read GT

 

Inactive PLU Read GT

All PLU Read GT

 

Zone PLU Read GT

 

All PLU Reset GT

 

Zone PLU Reset GT

 

NOTES: 1) CONSOLIDATION MEMORY CAPTURE: When an in-line read or reset report is taken on the Master Terminal, the consolidated data is automatically stored in the Consolidation Memory of the Master Terminal. The consolidated data stored there is not only used as the data for a Process Report but also sent to the PC by a command from the PC when a PC is connected.

2)The process reports will be outputted based on the report data previously collected. For example, when an “Inactive PLU Read” report is taken after a “Zone PLU Read”, only the inactive PLUs in the designated zone will be printed on the Inactive Read Report. (Only when the PLU is in a local file, a process report is printed. In this case, collection of data is required beforehand.)

4-6

Page 202
Image 202
Toshiba MA-1650-4 owner manual Customer File Read, # → File Code @/FOR → AT/TL, Process Reports and Base Report Data