6. REFRIGERANT CYCLE DIAGRAM

6-1. Refrigerant Cycle Diagram

RAS-10YKV-E/RAS-10YAV-E

RAS-13YKV-E/RAS-13YAV-E

PPressure measurement

Gauge attaching port

Vacuum pump connecting port

Deoxidized copper pipe

Outer dia. : 9,52mm

Thickness : 0,8mm

INDOOR UNIT

Indoor heat

exchanger

Cross flow fan

Deoxidized copper pipe Outer dia. : 6,35mm Thickness : 0,8mm

Sectional shape of heat insulator

T1

Temp. measurement

Allowable height difference : 10m

Allowable pipe length

 

 

 

Max. : 15m

4-way valve (CHV-0213)

TS

Temp. measurement T2

Muffler

Strainer

Muffler

 

Pulse modulating

 

valve at liquid side

 

 

TD

 

(SEV15RC2)

 

 

 

Compressor

 

 

DA91A1F-44F

 

 

Outdoor heat

Split capillary

 

 

exchanger

 

 

Ø1,5 x 200

 

 

 

 

 

 

Ø1,5 x 200

 

 

 

TE

 

 

Propeller fan

 

 

Refrigerant amount : 0,8kg

OUTDOOR UNIT

NOTE :

Gas leak check position

 

 

 

Refrigerant flow (Cooling)

 

 

 

Refrigerant flow (Heating)

NOTE :

The maximum pipe length of this air conditioner is 15 m. The additional charging of refrigerant is unneces- sary because this air conditioner is designed with charge-less specification.

– 19 –

Page 19
Image 19
Toshiba service manual Refrigerant Cycle Diagram, RAS-10YKV-E/RAS-10YAV-E RAS-13YKV-E/RAS-13YAV-E