Toshiba RAS-10YKV-E, RAS-13YKV-E, RAS-10YAV-E Auto Restart Function, How to Set the Auto Restart

Models: RAS-13YAV-E RAS-10YAV-E RAS-10YKV-E RAS-13YKV-E

1 79
Download 79 pages 58.17 Kb
Page 33
Image 33
8-4. Auto Restart Function

8-4. Auto Restart Function

This unit is equipped with an Automatic restarting facility which allows the unit to restart and resume the set operating conditions in the event of a power supply shutdown without the use of the hand control.

The operation will resume without warning three minutes after the power is restored.

The Auto Restart function is set not to work on shipment from the factory, and so it is necessary to set it to function as required.

• When the system is stand-by (not operating)

8-4-1. How to Set the Auto Restart

To set the Auto Restart function, proceed as follows:

Access the TEMPORARY button located in the lower right hand corner beneath the hinged front panel of the indoor unit (please refer to Fig. 8-2-9). The power supply to the unit must be on - the function will not be set if the power is off.

To enable the Auto Restart function, push the TEMPORARY button continuously for three seconds.

The unit will acknowledge the setting and beep three times. The system will now restart automatically.

The above Auto Restart settings can be carried out:

Operation

 

Motion

 

 

 

 

Push the TEMPORARY button

Stand-by

 

continuously more than three

 

seconds.

The system starts to operate.

The green light goes on.

 

 

 

 

about three seconds after

0

The unit beeps three times.

The orange light goes on.

 

3S

 

 

 

 

 

 

TEMPORARY

The system is operating.

 

 

 

If the system is not required to run at this time, push the TEMPORARY

 

 

 

 

button once more or use the remote controller and the unit will stop.

 

 

 

 

 

 

• When the system is operating

 

 

 

 

 

 

Operation

 

Motion

 

 

 

 

Push the TEMPORARY button

Operating

The green light goes on.

continuously more than three

 

seconds.

The system stops to operate.

The green light goes off.

 

 

 

 

about three seconds after

0The unit beeps three times.

3S

The system stops.

TEMPORARY 8-4-1. How to Set the Auto Restart

If the system is not required to stop at this time, use the remote controller and to restart.

During subsequent operation, the orange light goes on.

The Auto Restart function will not accept an instruction if timer operation with the remote controller is selected.

During louver swing (AUTO) operation, after restart by the Auto Restart function the louver swing stops.

– 33 –

Page 33
Image 33
Toshiba RAS-10YKV-E, RAS-13YKV-E, RAS-10YAV-E, RAS-13YAV-E service manual Auto Restart Function, How to Set the Auto Restart