8-4. Auto Restart Function
This unit is equipped with an Automatic restarting facility which allows the unit to restart and resume the set operating conditions in the event of a power supply shutdown without the use of the hand control.
The operation will resume without warning three minutes after the power is restored.
The Auto Restart function is set not to work on shipment from the factory, and so it is necessary to set it to function as required.
• When the system is
8-4-1. How to Set the Auto Restart
To set the Auto Restart function, proceed as follows:
Access the TEMPORARY button located in the lower right hand corner beneath the hinged front panel of the indoor unit (please refer to Fig.
To enable the Auto Restart function, push the TEMPORARY button continuously for three seconds.
The unit will acknowledge the setting and beep three times. The system will now restart automatically.
The above Auto Restart settings can be carried out:
Operation |
| Motion | |
|
|
|
|
Push the TEMPORARY button |
| ||
continuously more than three | ↓ |
| |
seconds. | The system starts to operate. | The green light goes on. | |
|
| ||
|
| ↓ about three seconds after | |
0 | The unit beeps three times. | The orange light goes on. | |
| 3S | ||
|
|
| |
|
| ↓ |
|
TEMPORARY | The system is operating. |
| |
|
| If the system is not required to run at this time, push the TEMPORARY | |
|
| ||
|
| button once more or use the remote controller and the unit will stop. | |
|
| ||
|
|
|
|
• When the system is operating |
|
| |
|
|
|
|
Operation |
| Motion | |
|
|
|
|
Push the TEMPORARY button | Operating | The green light goes on. | |
continuously more than three | ↓ |
| |
seconds. | The system stops to operate. | The green light goes off. | |
|
| ||
|
| ↓ about three seconds after |
0The unit beeps three times.
3S
↓
The system stops.
TEMPORARY
If the system is not required to stop at this time, use the remote controller and to restart.
During subsequent operation, the orange light goes on.
•The Auto Restart function will not accept an instruction if timer operation with the remote controller is selected.
•During louver swing (AUTO) operation, after restart by the Auto Restart function the louver swing stops.
– 33 –