5. SPECIFICATIONS OF ELECTRICAL PARTS

5. SPECIFICATIONS OF ELECTRICAL PARTS

5-1. Indoor Unit

RAS-10YKV-E, RAS-13YKV-E

No.

Parts name

Type

Specifications

 

 

 

 

1

Fan motor (for indoor)

TICF-35-19-4

DC35V, 19W

 

 

 

 

2

Thermo. sensor (TA-sensor)

( – )

10kat 25°C

 

 

 

 

3

DC-DC transformer (T01)

SWT-34 or SWT-46

DC390V, Secondary DC35V, 12V, 7V

 

 

 

 

4

Microcomputer

TMP87PM40AF or TMP87CM40AF

 

 

 

 

 

5

Heat exchanger temp. sensor

( – )

10kat 25°C

(TC-sensor)

 

 

 

 

 

 

 

6

Line filter (L01)

UF-253Y0R7

25mH, AC0,7A

 

 

 

 

7

Diode (DB01)

RBV-406 or D3SBA60

4A, 600V

 

 

 

 

8

Capacitor (C02)

KMH450VNSN100M25B

100µF, 450V

 

 

 

 

9

Fuse (F01)

TSCR6,3A

T6,3A, 250V

 

 

 

 

10

Power supply IC (IC01)

MA2830-FJ

4A, 600V

 

 

 

 

11

Varistor (R21, R109)

15G561K

560V

 

 

 

 

12

Resistor (R01)

ERF-5TK5R6

5,6, 5W

 

 

 

 

13

Louver motor

MP35EA7

Output (Rated) 2W, 10poles, 1phase DC12V

 

 

 

 

5-2. Outdoor Unit

RAS-10YAV-E, RAS-13YAV-E

No.

Parts name

Model name

 

Rating

 

 

 

 

 

1

SC coil

L03

SC-15-S06J

15A, 0,6mH

(Noise filter)

L01

SC-20-01J

20A, 150µH

 

 

 

 

 

 

2

DC-DC transformer

SWT-43

Primary side DC280V, Secondary side

7,5V x 1, 13V x 1, 26,5V x 3, 16V x 1, 15V x 1

 

 

 

 

 

 

 

 

 

3

Reactor

 

CH38Z-K

L=10mH, 16A x 2

 

 

 

 

4

Outside fan motor

ICF-140-40-7

DC140V, 40W

 

 

 

 

 

5

Fan control relay

AJQ1341

Coil DC12V

Contact AC125V, 3A

 

 

 

 

 

 

 

 

 

6

Suction temp. sensor

(Inverter attached)

10k

(25°C)

(TS sensor)

 

 

 

 

 

 

 

 

 

 

 

7

Discharge temp. sensor

(Inverter attached)

62k

(20°C)

(TD sensor)

 

 

 

 

 

 

 

 

 

 

 

8

Outside air temp. sensor

(Inverter attached)

10k

(25°C)

(TO sensor)

 

 

 

 

 

 

 

 

 

 

 

9

Heat exchanger temp.

(Inverter attached)

10k

(25°C)

sensor (TE sensor)

 

 

 

 

 

 

 

 

10

Terminal block (9P)

——

20A, AC250V

 

 

 

 

 

 

 

 

For protection of switching power source

3,15A, AC250V

 

 

 

 

 

11

Fuse

 

For protection of transistor module breakage

15A, AC250V

 

 

 

 

 

 

 

 

For protection of inverter input overcurrent

25A, AC250V

 

 

 

 

12

Electrolytic capacitor

LLQ2G501KHUATF, 400LISN500K35F

500µF, DC400V X 3 pieces

 

 

 

 

13

Transistor module

6MBI25GS-060-01 or 6MBI25GS-060-01A

25A, 600V

 

 

 

 

 

14

Compressor

 

DA91A1F-44F

3-phases 4-poles 750W

 

 

 

 

15

Compressor thermo.

US-622KXTMQO-SS

OFF: 125 ± 4°C, ON: 90 ± 5° C

 

 

 

 

16

Converter module

MP7003

Diode: 25A, 600V, IGBT: 40A, 600V

 

 

 

 

 

 

– 18 –