6-2. Operation Data

<Cooling>

Temperature condition (°C)

Indoor Outdoor

27/19

35/–

 

Standard

Heat exchanger

 

 

pipe temp.

Indoor fan

Model name

pressure

 

 

mode

 

P (MPa)

T1 (°C)

T2 (°C)

 

 

 

 

 

 

 

 

 

 

10YKV-E

0,8 to 1,0

9 to 11

42 to 44

High

 

 

 

 

 

13YKV-E

0,8 to 1,0

8 to 10

46 to 48

High

 

 

 

 

 

Outdoor fan

Compressor

revolution

mode

(rps)

 

High

56

 

 

High

85

 

 

<Heating>

Temperature condition (°C)

Indoor

Outdoor

 

 

20/–

7/6

 

 

 

Standard

Heat exchanger

 

 

 

pipe temp.

Indoor fan

Outdoor fan

Model name

pressure

 

 

mode

mode

 

P (MPa)

T1 (°C)

T2 (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

10YKV-E

3,5 to 3,7

42 to 44

2 to 4

High

High

 

 

 

 

 

 

13YKV-E

2,5 to 2,7

50 to 52

0 to 3

High

High

 

 

 

 

 

 

Compressor

revolution

(rps)

70

97

NOTES :

(1)Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor themometer)

(2)Connecting piping condition : 5 m

– 20 –

Page 20
Image 20
Toshiba RAS-13YKV-E, RAS-10YKV-E, RAS-10YAV-E, RAS-13YAV-E service manual Operation Data, Cooling, Heating