10-8-3. Indoor Unit (Other Parts)

No.

Part name

 

 

 

 

 

Checking procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Room temp. (TA) sensor

Disconnect the connector and measure the resistance value with tester.

 

Heat exchanger (TC) sensor

(Normal temp.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor

 

Temperature

10°C

20°C

25°C

30°C

40°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TA, TC (k)

20,7

12,6

10,0

7,9

4,5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Remote controller

To item of How to judge whether remote controller is good or bad of the

 

 

Judgment of trouble by symptom.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Louver motor

Measure the resistance value of each winding coil by using the tester.

 

MP35EA7

(Under normal temp. 25°C)

 

 

 

 

 

 

 

 

Position

 

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown

1

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 4

 

 

 

 

 

 

 

 

 

Red

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 6

 

 

130 ± 10

 

 

 

 

 

Orange

3

 

 

 

 

 

 

 

 

 

 

 

 

 

2 to 3

 

 

 

 

 

 

 

Yellow

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pink

5

 

 

 

2 to 5

 

 

 

 

 

 

 

 

 

Blue

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Indoor fan motor

Since judgment of DC motor is difficult on the single motor, refer to 10-

 

 

5-1. (3).

 

 

 

 

 

 

 

 

 

 

 

10-8-4. Outdoor Unit

No.

Part name

 

 

 

 

 

Checking procedure

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Compressor

Measure the resistance value of each winding by using the tester.

 

(Model : DA91A1F-44F)

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

- White

0,51 to 0,57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White - Black

0,51 to 0,57

 

 

 

 

White

Black

 

Black - Red

0,51 to 0,57

 

 

 

 

 

 

 

Under 20°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Outdoor fan motor

Measure the resistance value of winding by using the tester.

 

 

 

(Model : ICF-140-40-7)

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position

Resistance value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow- Pink

5 to 20 k

 

 

 

 

 

 

 

 

 

4 Pink

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 Gray

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

Black

For details, refer to Section 10-9.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Compressor thermo. Bimetal

Check conduction by using the tester.

 

 

 

 

 

type (Model : PW - 2AL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Outdoor temperature sensor

Disconnect the connector, and measure resistance value with the tester.

 

(TO), discharge temperature

(Normal temperature)

 

 

 

 

 

 

 

 

 

 

sensor (TD), suction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

10°C

 

20°C

30°C

40°C

50°C

 

 

temperature sensor (TS),

 

 

 

 

 

 

Sensor

 

 

 

 

 

outdoor heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TD (k)

 

105

64

41

27

18

 

 

temperature sensor (TE)

 

 

 

 

TGa : Heat pump model only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO, TS, TE : Refer to the TA, TC characteristic table in Indoor (Refer to

 

 

Table 10-8-3, No. 1).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 