Toshiba RAS-10YKV-E Block distinction, Cause of operation, Remarks, Judgment and action, status

Models: RAS-13YAV-E RAS-10YAV-E RAS-10YKV-E RAS-13YKV-E

1 79
Download 79 pages 58.17 Kb
Page 45
Image 45
– 45 –

Block distinction

 

Operation of diagnosis function

 

 

 

 

 

 

 

 

 

 

Check

Block

Check

Cause of operation

Air

 

Remarks

Judgment and action

conditioner

 

 

code

code

 

 

 

 

status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

 

Inverter over-current

All off

 

Displayed when

Even if trying operation again, all

 

P.C. board

 

protective circuit

 

 

error is detected.

operations stop immediately. : Replace

 

 

 

operates. (Short time)

 

 

 

P.C. board.

 

 

 

 

 

 

 

 

 

 

 

Position-detect circuit

All off

 

Displayed when

1. Even if connecting lead wire of

 

 

 

error or short-circuit

 

 

error is detected.

compressor is removed, position-

 

 

 

between windings of

 

 

 

detect circuit error occurred. :

 

 

 

compressor

 

 

 

Replace P.C. board.

 

 

 

 

 

 

 

2. Measure resistance between wires

 

 

 

 

 

 

 

of compressor, and perform short-

 

 

 

 

 

 

 

circuit. : Replace compressor.

 

 

 

 

 

 

 

 

 

 

 

Current-detect circuit

All off

 

Displayed when

Even if trying operation again, all

 

 

 

error

 

 

error is detected.

operations stop immediately. :

 

 

 

 

 

 

 

Replace P.C. board.

 

 

 

 

 

 

 

 

 

 

 

Being out of place,

All off

 

Displayed when

1. Check outdoor temp. sensors

 

 

 

disconnection or short-

 

 

error is detected.

(TE, TS).

 

 

 

circuit of outdoor temp.

 

 

 

2. Check P.C. board.

 

 

 

sensor

 

 

 

 

 

 

 

Disconnection or short-

All off

 

Displayed when

1. Check discharge temp. sensor (TD).

 

 

 

circuit of discharge temp.

 

 

error is detected.

2. Check P.C. board

 

 

 

sensor

 

 

 

 

 

 

 

Outdoor fan drive system

All off

 

Displayed when

Position-detect error, over-current

 

 

 

error

 

 

error is detected.

protective operation of outdoor fan

 

 

 

 

 

 

 

drive system, fan lock, etc. :

 

 

 

 

 

 

 

Replace P.C. board or fan motor.

 

 

 

 

 

 

 

 

 

Not

 

Outdoor heat exchanger

Operation

 

 

1. Check outdoor heat exchanger temp.

 

displayed

 

temp. sensor error

continues

 

——

sensor (TE).

 

 

 

 

 

 

 

2. Check P.C. board.

 

 

 

 

 

 

 

 

 

Outdoor

 

Compressor drive output

All off

 

Displayed when

When 20 seconds passed after start-

 

P.C. board

 

error, Compressor error

 

 

error is detected.

up, position-detect circuit error

 

 

 

(lock, missing, etc.),

 

 

 

occurred. : Replace compressor.

 

 

 

Break down

 

 

 

 

 

 

 

 

 

 

 

 

 

Others

 

Return serial signal has

Operation

 

Flashes when

1. Repeat Start and Stop with interval

 

(including

 

been sent when

continues

 

trouble is detected

of approx. 10 to 40 minutes. (Code is

 

compressor)

 

operation started, but it

 

 

on Return serial

not displayed during operation.)

 

 

 

is not sent from halfway.

 

 

signal, and normal

Supply gas. (Check also gas leak).

 

 

 

(1) Compressor thermo.

 

 

status when signal

2. Unit operates normally during check.

 

 

 

operation

 

 

is reset.

If Return serial signal does not stop

 

 

 

Gas shortage

 

 

 

between indoor terminal block 2 and

 

 

 

Gas leak

 

 

 

3, replace inverter P.C. board.

 

 

 

(2) Instantaneous power

 

 

 

If signal stops between indoor

 

 

 

failure

 

 

 

terminal block 2 and 3, replace

 

 

 

 

 

 

 

indoor P.C. board.

 

 

 

Compressor does not

All off

 

Displayed when

1. Trouble on compressor

 

 

 

rotate.

 

 

error is detected.

2. Trouble on wiring of compressor

 

 

 

(Current protective

 

 

 

(Missed phase)

 

 

 

circuit does not operate

 

 

 

 

 

 

 

when a specified time

 

 

 

 

 

 

 

passed after compressor

 

 

 

 

 

 

 

had been activated.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge temp.

All off

 

Displayed when

1. Check dischage temp. sensor (TD).

 

 

 

exceeded 117°C

 

 

error is detected.

2. Degassing

 

 

 

 

 

 

 

3. Trouble on P.M.V.

 

 

 

 

 

 

 

 

 

 

 

Break down of

All off

 

Displayed when

1. Check power voltage.

 

 

 

compressor

 

 

error is detected.

(220–30–40 V+10%)

 

 

 

 

 

 

 

2. Overload operation of refrigeration

 

 

 

 

 

 

 

cycle

 

 

 

 

 

 

 

Check installation condition

 

 

 

 

 

 

 

(Short-circuit of outdoor diffuser).

 

 

 

 

 

 

 

 

 

 

 

Four-way valve inverse

Operation

 

 

1. Check four-valve operation.

 

 

 

error

continues

 

 

 

 

 

 

(TC sensor value

 

 

——

 

 

 

 

lowered during heating

 

 

 

 

 

 

 

operation.)

 

 

 

 

 

 

 

 

 

 

 

 

– 45 –

Page 45
Image 45
Toshiba RAS-10YKV-E, RAS-13YKV-E, RAS-10YAV-E Block distinction, Cause of operation, Remarks, Judgment and action, status