Toshiba RAS-10YAV-E Judgment of Trouble by Every Symptom, Indoor Unit Including Remote Controller

Models: RAS-13YAV-E RAS-10YAV-E RAS-10YKV-E RAS-13YKV-E

1 79
Download 79 pages 58.17 Kb
Page 46
Image 46
10-5. Judgment of Trouble by Every Symptom

10-5. Judgment of Trouble by Every Symptom

 

 

10-5-1. Indoor Unit (Including Remote Controller)

 

 

(1) Power is not turned on (Does not operate entirely)

 

Operation

 

 

 

 

 

 

 

Check Item

 

Turn off the power supply

 

 

 

Considerable main cause

 

once, and turn on it again

 

 

 

 

 

after 5 seconds passed.

 

 

 

Measures

 

 

 

 

 

NO

Does the operation

 

 

 

Item by symptom

 

lamp flash?

 

 

 

 

YES

 

 

 

 

 

Is the power supply

NO

Does send display

NO

 

 

turned on by pressing

of remote controller flash

Remote controller

 

 

 

 

[START/STOP] button

 

normally, and is the signal

 

error

 

on remote controller?

 

sent securely?

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

(No trouble)

 

Is fuse of indoor control

YES

Parts (R21, R109, SG01,

 

board blown? (F01)

 

 

 

 

C15, C01, DB01, C02,

 

 

 

 

 

 

 

 

IC01, T01) are defective.

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is temp. fuse blown?

YES

Connection of connecting

 

 

 

 

 

 

 

 

 

 

wire is defective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

Is voltage indicated

 

YES

 

 

 

NO on rear of indoor control

 

 

 

 

 

board (DC12V or 5V)

 

 

 

 

 

 

 

 

normal?

 

 

 

 

 

 

Is DC310 to 340V

NO

 

 

 

 

 

 

 

 

applied to primary

 

To item of Pre-check or

 

 

side of SW trans.

 

 

trouble before power board

(T01) applied?

 

 

 

 

 

 

 

 

 

Is DC35V,

 

 

 

 

 

 

 

 

Is DC35V,

NO

 

Turn “OFF” breaker

 

 

DC12V, DC7V

 

 

 

DC12V, DC7V

applied to secondary

 

 

once, and “ON”

 

 

applied to secondary

 

 

again after removing

 

 

side of SW trans.

 

 

 

 

side of SW trans.

 

 

motor.

 

 

 

 

 

(T01) applied?

 

 

 

 

 

 

 

(T01) applied?

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Microcomputer is defective.

SW trans.,

IC (IC01) for power supply, ] or fan motor

Refer to the item of Remote controller check. (p.49)

Replace temp. fuse set.

Check connecting wire.

Replace main board.

Motor is defective.

Be sure to disconnect the motor connector CN10 after shut off the power supply, or it will be a cause of damage of the motor.

(2) Power is not turned on though Indoor P.C. board is replaced

<Confirmation procedure>

Turn on power supply.

 

 

NO

Is wired correctly to white and black

NO

Does operation lamp flash?

 

 

 

lead wires of terminal block?

 

 

 

 

 

 

YES

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Correct wiring.

To item of “Power supply is not turned on”.

– 46 –

Page 46
Image 46
Toshiba RAS-10YAV-E Judgment of Trouble by Every Symptom, Indoor Unit Including Remote Controller, Confirmation procedure