10-3. Judgment by Flashing LED of Indoor Unit

While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the contents of self-diagnosis are displayed with block on the indoor unit indication section.

Table 10-3-1

Indoor

indication lamp flashes.

Which lamp does flash?

Item

Check

Block display

Description for self-diagnosis

code

 

 

 

 

OPERATION

OPERATION (Green)

Power failure (when power is ON)

A

ECONO.

 

 

TIMER

Flashing display (1 Hz)

 

 

 

 

PRE DEF.

 

 

 

OPERATION

OPERATION (Green)

Protective circuit operation for

B

ECONO.

 

indoor P.C. board

TIMER

Flashing display (5 Hz)

 

 

 

 

PRE DEF.

 

 

 

OPERATION

OPERATION (Green)

Protective circuit operation for

C

ECONO.

TIMER (Yellow)

connecting cable and serial signal

TIMER

system

 

 

 

PRE DEF.

Flashing display (5 Hz)

 

 

OPERATION

OPERATION (Green)

Protective circuit operation for

D

ECONO.

PRE DEF. (Orange)

outdoor P.C. board

TIMER

 

 

Flashing display (5 Hz)

 

 

PRE DEF.

 

 

OPERATION

OPERATION (Green)

Protective circuit operation for others

E

ECONO.

TIMER (Yellow)

(including compressor)

TIMER

PRE DEF. (Orange)

 

 

 

 

PRE DEF.

Flashing display (5 Hz)

 

NOTES :

(1)The contents of items B and C and a part of item E are displayed when air conditioner operates.

(2)When item B and C, and item B and a part of item E occur concurrently, priority is given to the block of item B.

(3)The check codes can be confirmed on the remote controller for servicing.