ˆDrain pump 1. Detachment

No. Part name

Procedure

Remarks

ˆDrain pump 1. Detachment

assembly

1)

Perform works of items 1 of , 1 of ,

Slide to hose side.

 

 

1 of ƒ, 1 of and 1 of .

 

 

2)

Picking the hose band, slide it from

 

 

 

pump connecting part to remove the

 

 

 

drain hose.

 

3) Remove screw fixing the drain pump

 

assembly, slide hooking claws of the

 

drain pump assembly and the main

Hose band

body (1 position), and then remove the

 

assembly. (Ø4 × 8, 3 pcs.)

 

3. Attachment

1) Fix the drain pump assembly as before.

Pump connecting part

NOTE :

The drain pump is fixed with a hook and 3 screws. In screwing, be sure that screws do not to run on hooking claw at the main body side.

2) Attach the drain hose and hose band as before.

NOTE :

Hooking claw

Insert the drain hose up to the end of pump connecting part, and bind the white mark position of the hose with band.

Fixing screw