Compressor

 

 

 

1 1

RED

CM

2 2

WHI

 

3 3

BLK

 

YEL

P25

 

 

P24

 

YEL

P23

 

 

P22

 

BRW

P21

CAUTION : HIGH VOLTAGE

 

P20

The high voltage circuit is

YEL

P35

incorporated.

 

P34

Be careful to do the check service,

 

 

as the electric shock may be

 

 

caused in case of touching

 

 

parts on the

 

 

P.C. board by hand

 

 

P04

 

 

 

 

 

 

CN300

3 3

BLK

FM

P05

Q200~205

 

P.C. Board

Q300~305

 

 

2

2

WHI

P06

IGBT

 

MOS-FET

 

 

1

1

RED

 

 

R221

 

(MCC-5009)

R321

 

 

 

 

 

Fan motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

6

 

 

 

R220

 

 

 

R320

 

 

5

5

 

 

 

 

 

 

 

 

 

 

4

4

 

PMV

 

 

 

 

 

 

 

CN700

3

3

 

 

R219

 

 

 

R319

 

 

 

 

 

 

 

 

2 2

 

 

 

 

 

 

 

 

 

 

1

1

Pulse motor valve

 

 

 

 

F03

 

 

 

 

 

 

 

 

 

 

Varistor

 

 

 

 

 

 

L03

C13

Fuse

L01

 

 

 

3 3

 

 

 

 

 

T3.15A

 

 

 

 

 

 

 

 

 

 

AC250V

 

 

 

 

 

2

 

 

DB01

 

 

 

 

 

 

CN603

1 1

 

 

 

 

 

 

Surge

 

 

 

 

 

TS

 

 

 

 

 

 

 

 

 

 

(Suction pipe

 

 

C12

C14

 

absorber

 

 

 

 

2 2

temp. sensor)

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

CN602

1 1

 

 

 

 

 

Varistor

 

 

 

 

TO

 

relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temp. sensor)

RAV-

5-2.

SM562AT-E, RAV-SM802AT-E

Outdoor Unit (Wiring Diagram)

– 42 –

The 4-way valve coil is turned on while the cooling operation

NOTE

P19

ORN

P18

2 2 P11 Reactor 1 1 P08

DB02

CT

 

 

3

3

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

F01

CN601

1

1

 

 

Relay

Fuse

 

 

 

TD

 

T25A

 

 

 

(Discharge pipe

 

 

AC250V

 

2

2

temp. sensor)

 

 

 

 

 

 

 

CN600

1

1

 

Q404

P03 P10

P02

TE

(Condenser pipe

CM

: Compressor

PMV

: Pulse motor valve

FM

: Fan motor

TE

: Heat exchanger Temp. Sensor

TD

: Discharge Temp. Sensor

TO

: Outdoor Temp. Sensor

TS

: Suction Temp. Sensor

IGBT

: Insulated Gate Bipolar Transistor

DB01

: Converter module

CT

: Curreut Transformer

Color Identification

BLK

: BLACK

WHI :

WHITE

BLU

: BLUE

BRN :

BROWN

RED

: RED

ORN :

ORANGE

GRY

: GRAY

YEL :

YELLOW

PNK

: PINK

PUR :

PURPLE

P33

P32

CN701

P7

ORN BLK

WHI CN806

temp. sensor)

1

2

3

CN605

P31

P30

1

3

BLK

 

 

ORN

BLK

WHI

1 2 3 4 5

1

2

3

BLK

 

2 1

1

3

 

 

 

For optional P.C. Board

RED WHI BLK

PUR

 

2 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil for

Reactor

 

 

 

 

1

2

3

 

 

 

 

 

4-WAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW802

 

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

 

 

 

 

Reactor

 

 

Fuse 250V~

 

 

 

 

 

 

 

 

 

 

WHI

RED

 

WHI

 

MCC-1530

 

 

 

 

T6.3A

RED

 

 

 

 

 

 

 

 

 

 

 

Sub P.C. Board

 

 

 

 

 

 

 

 

 

 

 

1 2 3 L N

To indoor

Power supply

 

220-240V~ 50Hz

 

220V~ 60Hz

Page 42
Image 42
Toshiba RAV-SM802UT-E, RAV-SM1102UT-E, RAV-SM1402UT-E Board, MCC-5009, SM562AT-E, RAV-SM802AT-E, Color Identification

RAV-SM562UT-E, RAV-SM802UT-E, RAV-SM1402UT-E, RAV-SM1102UT-E specifications

Toshiba has established itself as a leading name in the field of heating, ventilation, and air conditioning (HVAC) systems. Among their extensive range, the RAV-SM802UT-E, RAV-SM1102UT-E, RAV-SM1402UT-E, and RAV-SM562UT-E stand out for their performance, efficiency, and innovative technology.

The Toshiba RAV-SM802UT-E is designed for medium-sized commercial spaces, providing a cooling capacity of 8 kW. It employs advanced inverter technology, which enables it to adjust the compressor speed based on the load demand. This adaptability leads to a significant decrease in energy consumption, making the unit both eco-friendly and cost-effective. The unit also features a high-efficiency rotary compressor and a wide operating temperature range, ensuring reliable performance even in extreme weather conditions.

Next in line, the RAV-SM1102UT-E offers an impressive 11 kW cooling capacity, making it suitable for larger commercial applications. This model incorporates Toshiba’s cutting-edge Superlink technology, which allows multiple indoor units to be connected to a single outdoor unit, providing flexible installation options. The RAV-SM1102UT-E is also equipped with a sleek and modern design that blends seamlessly with any architecture while ensuring low noise levels during operation, enhancing comfort in the workspace.

The RAV-SM1402UT-E is a powerhouse among the series, boasting a cooling capacity of 14 kW. It is built with an enhanced refrigerant management system that minimizes refrigerant leaks and optimizes thermal efficiency. This model supports smart building management systems, making it an ideal choice for tech-savvy businesses looking to integrate their HVAC systems into a broader energy management framework. Furthermore, it maintains high EU energy efficiency ratings, verifying Toshiba's commitment to environmental sustainability.

Lastly, the RAV-SM562UT-E, with its 5.6 kW cooling capacity, is tailored for smaller commercial environments and residential use. It retains all the core technologies featured in its counterparts, including inverter technology and a high-efficiency compressor, ensuring comfort without excessive energy usage. This model also includes a user-friendly remote control and programmable timer functions, allowing for customized comfort settings and enhanced convenience.

In summary, the Toshiba RAV-SM series represents the pinnacle of HVAC innovation, blending energy efficiency with advanced technology. Each model caters to specific needs, from the compact RAV-SM562UT-E to the robust RAV-SM1402UT-E, ensuring that every commercial and residential space can achieve optimal climate control.