Toshiba RAV-SM1402UT-E, RAV-SM1102UT-E 49, RAV-SM1402AT-E, RAV-SP562AT-E, RAV-SP802AT-E

Models: RAV-SM562UT-E RAV-SM802UT-E RAV-SM1402UT-E RAV-SM1102UT-E

1 196
Download 196 pages 53.59 Kb
Page 49
Image 49

RAV-SM1402AT-E

No.

Parts name

Type

 

Specifications

 

 

 

 

1

Fan motor

ICF-280-100-1R

Output (Rated) 100 W

 

 

 

 

2

Compressor

DA420A3F-21M

3 phase, 4P, 3500 W

 

 

 

 

3

Reactor

CH-62

6 mH, 18.5 A

 

 

 

 

 

4

Outdoor temp. sensor (To-sensor)

10 k

at 25°C

 

 

 

 

 

5

Heat exchanger sensor (Te-sensor)

10 k

at 25°C

 

 

 

 

 

6

Suction temp. sensor (Ts-sensor)

10 k

at 25°C

 

 

 

 

 

7

Discharge temp. sensor (Td-sensor)

50 k

at 25°C

 

 

 

 

8

Fuse (Switching power (Protect))

T3.15 A, AC 250 V

 

 

 

 

9

Fuse (Inverter, input (Current protect))

25 A, AC 250 V

 

 

 

 

10

4-way valve solenoid coil

VHV-01AJ503C1

AC 220 – 240 V

 

 

 

 

11

Compressor thermo. (Protection)

US-622

ON : 90 ± 5°C, OFF : 125 ± 4°C

 

 

 

 

 

12

Coil (Pulse Motor Valve)

UKV-048E

 

 

 

 

 

 

RAV-SP562AT-E, RAV-SP802AT-E

No.

Parts name

Type

 

Specifications

 

 

 

 

1

Fan motor

ICF-140-63-2R

Output (Rated) 63 W

 

 

 

 

2

Compressor

DA220A2F-20LR

3 phase, 4P, 2000 W

 

 

 

 

3

Reactor

CH-47

8 mH, 16 A

 

 

 

 

 

4

Outdoor temp. sensor (To-sensor)

10 k

at 25°C

 

 

 

 

 

5

Heat exchanger sensor (Te-sensor)

10 k

at 25°C

 

 

 

 

 

6

Suction temp. sensor (Ts-sensor)

10 k

at 25°C

 

 

 

 

 

7

Discharge temp. sensor (Td-sensor)

50 k

at 25°C

 

 

 

 

8

Fuse (Switching power (Protect))

T3.15 A, AC 250 V

 

 

 

 

9

Fuse (Inverter, input (Current protect))

25 A, AC 250 V

 

 

 

 

 

10

4-way valve solenoid coil

VHV-01AJ503C1

 

 

 

 

 

 

11

Compressor thermo. (Protection)

US-622

ON : 90 ± 5°C, OFF : 125 ± 4°C

 

 

 

 

 

12

Coil (Pulse Motor Valve)

DKV-025743B0

 

 

 

 

 

 

13

Reactor

CH-43

10 mH, 1 A

 

 

 

 

 

RAV-SP1102AT-E, RAV-SP1402AT-E

No.

Parts name

Type

 

Specifications

 

 

 

 

1

Fan motor

ICF-140-63-2R

Output (Rated) 63 W

 

 

 

 

2

Compressor

DA420A3F-21M

3 phase, 4P, 3500 W

 

 

 

 

3

Reactor

CH-62

6 mH, 18.5 A

 

 

 

 

 

4

Outdoor temp. sensor (To-sensor)

10 k

at 25°C

 

 

 

 

 

5

Heat exchanger sensor (Te-sensor)

10 k

at 25°C

 

 

 

 

 

6

Suction temp. sensor (Ts-sensor)

10 k

at 25°C

 

 

 

 

 

7

Discharge temp. sensor (Td-sensor)

50 k

at 25°C

 

 

 

 

8

Fuse (Switching power (Protect))

T3.15 A, AC 250 V

 

 

 

 

9

Fuse (Inverter, input (Current protect))

25 A, AC 250 V

 

 

 

 

10

4-way valve solenoid coil

VHV-01AJ502E1

AC 220 V

 

 

 

 

11

Compressor thermo. (Protection)

US-622

ON : 90 ± 5°C, OFF : 125 ± 4°C

 

 

 

 

 

12

Coil (Pulse Motor Valve)

UKV-U011E

 

 

 

 

 

 

– 49 –

Page 49
Image 49
Toshiba RAV-SM1402UT-E, RAV-SM1102UT-E 49, RAV-SM1402AT-E, RAV-SP562AT-E, RAV-SP802AT-E, RAV-SP1102AT-E, RAV-SP1402AT-E