4.27 Fluorescent Lamp 4 Replacement Procedure
6. Install the lamp cover (F) and secure it with the two screws (E).
NOTE: Be careful not to make the lamp cover over the fitting pin. Around the pulling-out
part of the lead wire, attach so that the P chassis is outside.
(E) Screw tightening torque:
0.1176Nm
(
1.2k
g
fcm
)
(F) Lamp cover
(
E
)
Figure 4-76 Replacing Sharp fluorescent lamp (SXGA+) (6)
TECRA M2 Maintenance Manual (960-468) 4-103