4 Replacement Procedure 4.27 Fluorescent Lamp
9. Install the protection cover S (A), protection cover G (B), aluminum tape (C) and
fixing tape for lead wire (D). Use new parts.
Stick the protection covers in the order of (B), (A) to the standard line for
fitting pin.
Stick the aluminum tape (C) following the sticking standards.
Long sides: Stick to the mark-off line of the lamp cover on the back of bezel.
Short sides: Stick to the edge of lamp cover.
Stick the fixing tape for lead wire (D) following the sticking standards.
Long sides: Stick to the outline of the LCD module.
Short sides: Stick so that the wire covers the screws.
(B) Protection cover G
(C) Aluminum tape
Latch
(D) Fixing tape
for lead wire
(A) Protection cover S
Figure 4-79 Replacing Sharp fluorescent lamp (SXGA+) (9)
4-106 TECRA M2 Maintenance Manual (960-468)