efesotomasyon.com -Toshiba inverter,drive,servo,plc

 

 

 

 

 

 

 

E6581315

 

 

 

 

 

 

 

 

 

Com-

 

 

 

 

 

 

 

 

munica-

Title

Function

Adjustment range

Unit

Default

Valid

Reference

 

tion

setting

 

 

 

 

 

 

 

 

Number.

 

 

 

 

 

 

 

 

 

 

 

0:Slave (issues a 0Hz command if some-

 

 

 

 

 

 

 

 

thing goes wrong with the master)

 

 

 

 

 

 

 

 

1:Slave (continues operation if something

 

 

 

 

 

 

 

Inverter-to-inverter

goes wrong with the master)

 

 

 

 

 

 

 

2:Slave (trips for emergency stop if

 

 

 

 

 

0826



communication

something goes wrong with the master)

-

0

After reset.

Chapter 6

 

setting (4-wire

 

 

 

RS485)

3:Master (sends a frequency command)

 

 

 

 

 

 

 

4:Master (sends an output frequency)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.Master (sends a torque command)

 

 

 

 

 

 

 

 

6.Master (sends an output torque com-

 

 

 

 

 

 

 

 

mand)

 

 

 

 

 

0829



Protocol selection

0: TOSHIBA

-

0

After reset.

Chapter 3

 

(4-wire RS485)

1: MODBUS-RTU

 

0870



Block write data 1

0: Deselect

 

 

 

 

 

1: Command information 1 (FA00)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Command information 2 (FA20)

 

 

 

 

 

 

 

 

3: Frequency command (FA01)

-

0

After reset.

Section

 

0871



Block write data 2

4: Terminal board output data

4.1.3

 

 

 

 

 

(FA50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5: Communication analog data

 

 

 

 

 

 

 

 

(FA51)

 

 

 

 

 

0875



Block read data 1

0: Deselect

 

 

 

 

 

1: Status information (FD01)

 

 

 

 

 

 

 

 

 

 

 

 

 

0876

 

Block read data 2

 

 

 

 

 



2: Output frequency (FD00)

 

 

 

 

 

 

 

 

3: Output current (FD03)

 

 

 

 

 

0877



Block read data 3

 

 

 

 

 

4: Output voltage (FD05)

 

 

 

 

 

0878



Block read data 4

5: Alarm information (FC91)

 

 

 

 

 

6: PID feedback value (FD22)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7: Input terminal board monitor (FD06)

 

 

 

 

 

 

 

 

8: Output terminal board monitor (FD07)

 

 

 

 

 

 

 

 

9: VI/IIterminal board monitor (FE36)

-

0

After reset.

Section

 

 

 

 

10: RR/S4 terminal board monitor (FE35)

4.1.3

 

 

 

 

 

 

 

 

 

 

 

11:RX terminal board monitor (FE37)

 

 

 

 

 

0879

 

Block read data 5

12:Input voltage (DC detection) (FD04)

 

 

 

 

 



13:Speed feedback frequency (FD16)

 

 

 

 

 

 

 

 

14:Torque (FD18)

 

 

 

 

 

 

 

 

15:MY monitor 1 (FE60)

 

 

 

 

 

 

 

 

16:MY monitor 2 (FE61)

 

 

 

 

 

 

 

 

17:MY monitor 3 (FE62)

 

 

 

 

 

 

 

 

18:MY monitor 4 (FE63)

 

 

 

 

 

 

 

 

19:Free notes (F880)

 

 

 

 

 

0880



Free notes

0-65535

1

0

Real time

Section 7.5

 

 

 

 

 

 

 

 

 

 

41

Page 42
Image 42
Toshiba TOSVERT VF-AS1 instruction manual Modbus-Rtu